Evaluation of the Biomechanical Parameters of Human-Wheelchair Systems during Ramp Climbing with the Use of a Manual Wheelchair with Anti-Rollback Devices

Author:

Wieczorek BartoszORCID,Kukla MateuszORCID,Rybarczyk DominikORCID,Warguła ŁukaszORCID

Abstract

Purpose: The main purpose of the research conducted was the analysis of kinematic and biomechanical parameters measured during manual wheelchair ramp-climbing with the use of the anti-rollback system and the comparison of the values tested with the manual wheelchair climbing the same ramp but without any modifications. The paper presents a quantitative assessment relating to the qualitative research of the anti-rollback system performed by another research team. Method and materials: The article presents the measurement results of the wheelchair motion kinematics and the activity of four upper limb muscles for eight subjects climbing a 4.58° ramp. Each subject propelled the wheelchair both with and without the anti-rollback system. The kinematic parameters were measured by means of two incremental encoders with the resolution of 500 impulses per single revolution of the measurement wheel. Whereas, the muscle activity was measured by means of surface electromyography with the use of Noraxon Mini DTS apparatus equipped with four measurement channels. Results: The surface electromyography measurement indicated an increase in the muscle activity for all four muscles, during the use of the anti-rollback system. The increase was: 18.56% for deltoid muscle anterior, 12.37% for deltoid muscle posteriori, 13.0% for triceps brachii, and 15.44% for extensor carpi radialis longus. As far as the kinematics analysis is concerned, a decrease in the measured kinematic parameters was observed in most participants. The medium velocity of the propelling cycle decreased by 26%. The ratio of the generated power and the loss power in a single propelling cycle λ had decreased by 18%. The least decrease was recorded for the measurement of mechanical energy E and the propelling cycle duration time. For the total mechanical energy, the decrease level was 3%, and for the propelling cycle duration it was 1%. The research carried out did not demonstrate any impact of the anti-rollback system use on the push phase share in the entire propelling cycle.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3