Abstract
We analyzed the prognostic performance of optic nerve sheath diameter (ONSD) on thin-slice (0.6 mm) brain computed tomography (CT) reconstruction images as compared to routine-slice (4 mm) images. We conducted a retrospective analysis of brain CT images taken within 2 h after cardiac arrest. The maximal ONSD (mONSD) and optic nerve sheath area (ONSA) were measured on thin-slice images, and the routine ONSD (rONSD) and gray-to-white matter ratio (GWR) were measured on routine-slice images. We analyzed their area under the receiver operator characteristic curve (AUC) and the cutoff values for predicting a poor 6-month neurological outcome (a cerebral performance category score of 3–5). Of the 159 patients analyzed, 113 patients had a poor outcome. There was no significant difference in rONSD between the outcome groups (p = 0.116). Compared to rONSD, mONSD (AUC 0.62, 95% CI: 0.54–0.70) and the ONSA (AUC 0.63, 95% CI: 0.55–0.70) showed better prognostic performance and had higher sensitivities to determine a poor outcome (mONSD, 20.4% [95% CI, 13.4–29.0]; ONSA, 16.8% [95% CI, 10.4–25.0]; rONSD, 7.1% [95% CI, 3.1–13.5]), with specificity of 95.7% (95% CI, 85.2–99.5). A combined cutoff value obtained by both the mONSD and GWR improved the sensitivity (31.0% [95% CI, 22.6–40.4]) of determining a poor outcome, while maintaining a high specificity. In conclusion, rONSD was clinically irrelevant, but the mONSD had an increased sensitivity in cutoff having acceptable specificity. Combination of the mONSD and GWR had an improved prognostic performance in these patients.
Funder
The Catholic Medical Center Research Foundation made in the program year of 2022
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献