Enhanced µCT Imaging Protocol to Enable High-Resolution 3D Visualization of Microdamage in Rat Vertebrae

Author:

Tolgyesi Allison12ORCID,Robert Normand1,Whyne Cari M.123,Hardisty Michael13ORCID

Affiliation:

1. Orthopaedic Biomechanics Laboratory, Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada

2. Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada

3. Division of Orthopaedics, Department of Surgery, University of Toronto, Toronto, ON M5T 1P5, Canada

Abstract

Contrast-enhanced μCT imaging has been used to provide non-destructive 3D images of microdamage, but at a lower quality than found in histology and 2D backscatter electron (BSE) imaging. This study aimed to quantify potential improvements in microdamage characterization by enhancing µCT scanning parameters. Eleven slides from 9 rat vertebrae (healthy = 3, osteolytic metastases = 3, mixed metastases = 3) previously stained for microdamage with BaSO4 and analyzed with BSE imaging (2μm voxel spacing) were used in this study. μCT imaging conducted under varying protocols (x-ray voltage, tube current, frame averaging) demonstrated enhanced scan parameters at 90 kVp, 44 µA, 0.5 mm aluminum filter, 8 times frame averaging, and 4.9 µm voxel spacing. Post-processing with Richardson-Lucy deconvolution further deblurred the μCT images. Labeled microdamage in the baseline, enhanced and deblurred μCT images were segmented and spatially quantified vs. BSE-labeled microdamage using a probability-based correlation metric at six inflation radii. Enhanced μCT scan parameters improved damage visualization and increased spatial correlation probability with BSE images. Deblurring improved the sharpness of stain boundaries but did not significantly improve spatial correlation probabilities in comparison to the enhanced scans. This enhanced μCT protocol facilitates 3D visualization of microdamage, an indicator of bone quality important to bone damage mechanics.

Funder

the Canadian Institutes of Health Research

the Canadian Graduate Scholarships—Master’s

the Ontario Graduate Scholarship

the Feldberg Chair for Spinal Research

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Treatment affects load to failure and microdamage accumulation in healthy and osteolytic rat vertebrae;Journal of the Mechanical Behavior of Biomedical Materials;2024-03

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3