Intraoperative Beat-to-Beat Pulse Transit Time (PTT) Monitoring via Non-Invasive Piezoelectric/Piezocapacitive Peripheral Sensors Can Predict Changes in Invasively Acquired Blood Pressure in High-Risk Surgical Patients

Author:

Nordine Michael1,Pille Marius23,Kraemer Jan3,Berger Christian1ORCID,Brandhorst Philipp1,Kaeferstein Philipp4,Kopetsch Roland4,Wessel Niels35ORCID,Trauzeddel Ralf Felix1,Treskatsch Sascha1ORCID

Affiliation:

1. Department of Anesthesiology and Intensive Care Medicine, Hindenburgdamm 30, Charité–Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt Universität zu Berlin, 12203 Berlin, Germany

2. Berlin Institute of Health at Charité, Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin, Germany

3. Department of Physics, Humboldt University zu Berlin, 10115 Berlin, Germany

4. SectorCon-Ingenieurgesellschaft mbH, 10553 Berlin, Germany

5. Department of Human Medicine, MSB Medical School Berlin GmbH, 14197 Berlin, Germany

Abstract

Background: Non-invasive tracking of beat-to-beat pulse transit time (PTT) via piezoelectric/piezocapacitive sensors (PES/PCS) may expand perioperative hemodynamic monitoring. This study evaluated the ability for PTT via PES/PCS to correlate with systolic, diastolic, and mean invasive blood pressure (SBPIBP, DBPIBP, and MAPIBP, respectively) and to detect SBPIBP fluctuations. Methods: PES/PCS and IBP measurements were performed in 20 patients undergoing abdominal, urological, and cardiac surgery. A Pearson’s correlation analysis (r) between 1/PTT and IBP was performed. The predictive ability of 1/PTT with changes in SBPIBP was determined by area under the curve (reported as AUC, sensitivity, specificity). Results: Significant correlations between 1/PTT and SBPIBP were found for PES (r = 0.64) and PCS (r = 0.55) (p < 0.01), as well as MAPIBP/DBPIBP for PES (r = 0.6/0.55) and PCS (r = 0.5/0.45) (p < 0.05). A 7% decrease in 1/PTTPES predicted a 30% SBPIBP decrease (0.82, 0.76, 0.76), while a 5.6% increase predicted a 30% SBPIBP increase (0.75, 0.7, 0.68). A 6.6% decrease in 1/PTTPCS detected a 30% SBPIBP decrease (0.81, 0.72, 0.8), while a 4.8% 1/PTTPCS increase detected a 30% SBPIBP increase (0.73, 0.64, 0.68). Conclusions: Non-invasive beat-to-beat PTT via PES/PCS demonstrated significant correlations with IBP and detected significant changes in SBPIBP. Thus, PES/PCS as a novel sensor technology may augment intraoperative hemodynamic monitoring during major surgery.

Funder

German Government sponsored ZIM (Zentrales Innovationsprogramm Mittelstand) program

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference59 articles.

1. Optimal Perioperative Management of Arterial Blood Pressure;ReferencesLonjaret;IBPC,2014

2. Blood Pressure Targets in Perioperative Care: Provisional Considerations Based on a Comprehensive Literature Review;Meng;Hypertension,2018

3. Optimal Perioperative Blood Pressure Management;Packiasabapathy;Adv. Anesth.,2018

4. Perioperative Blood Pressure Management;Saugel;Anesthesiology,2021

5. Improving Perioperative Outcomes Through Minimally Invasive and Non-Invasive Hemodynamic Monitoring Techniques;Yamada;Front. Med.,2018

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献