Shaking Table Test for Seismic Response of Nuclear Power Plant on Non-Rock Site

Author:

Lu Xinyu1,Jing Liping12,Ma Ying13,Yang Jianhua3,Qi Wenhao1

Affiliation:

1. Key Laboratory of Earthquake Engineering and Engineering Vibration, Institute of Engineering Mechanics, China Earthquake Administration, Harbin 150080, China

2. Institute of Disaster Prevention, Sanhe 065201, China

3. China Nuclear Power Engineering Co., Ltd., Beijing 100840, China

Abstract

In order to compare and analyze the seismic response characteristics of a safety-related nuclear structure on a non-rock site in the condition of raft and pile group foundations under unidirectional and multidirectional seismic motion input, a large-scale shaking table test of the soil-nuclear structure system was carried out in this paper. In the test, the soil was uniform silted clay, and the shear wave velocity was 213 m/s. Considering the similarity of the superstructure natural frenquency, the actual nuclear power structure was simplified to a three-story frame shear wall structure model. The annular laminated shear model box was used to take the boundary effect of soil into consideration; the seismic motions = were input in only one horizontal direction or three directions at the same time for the shaking table test, and the results were analyzed. The results of the test show that the acceleration response of the safety-related nuclear plant is affected by the directions of input seismic motion and the forms of the foundation. When the seismic motion is input simultaneously in three directions, the acceleration responses of the horizontal motion and vertical rocking of the safety-related plant are larger than those of the single-direction input. The acceleration response of the horizontal motion and vertical rocking of the safety-related structure with the pile group foundation is smaller than that with the raft foundation. The values of most frequency bands in the horizontal acceleration Fourier amplitude spectrum at the top of the pile-foundation structure are smaller than that at the top of the raft-foundation structure, while the displacement is basically the same as that of the raft-foundation structure. This is related to the relation between the frequency component of input seismic motion and the natural frequency of the structure system. Therefore, it is more reasonable to use three-dimensional seismic input in the seismic response analysis of nuclear power plants. The seismic performance of nuclear power plants can be enhanced by using pile group foundations.

Funder

Scientific Research Fund of Institute of Engineering Mechanics, China Earthquake Administration

Publisher

MDPI AG

Subject

Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development,Building and Construction

Reference24 articles.

1. Du, N. (2019, January 20–23). Exploration and practice of quality assurance for haixing nuclear power plant soft foundation treatment. Proceedings of the Progress Report on China Nuclear Science and Technology (Roll VI)-Proceedings of the 2019 Annual Academic Meeting of the Chinese Nuclear Society Volume 10 (Nuclear Safety Subsection and Nuclear Security Subsection), Baotou, China.

2. Wang, F. (2021). Study on the Effect of Non-Rock Site on Seismic Behavior of Safety-Related Nuclear Structure, Institute of Geophysics, China Earthquake Administration.

3. Dynamic analysis for isolation structures of nuclear power plants;Chen;Ind. Constr.,2016

4. Earthquake response analysis of soil-pile-nuclear power station auxiliary workshop structure interaction system;Ying;Earthq. Eng. Eng. Dyn.,1995

5. Sayed, M., Kim, D., and Cho, S.G. (2013). Seismic Analysis of Base Isolated Nuclear Power Plant Considering Nonlinear Pile-Soil Interaction, Transactions, SMiRT-22.