Numerical Simulation of the Impact of Water Vapour and Moisture Blockers in Energy Diagnostics of Ventilated Partitions

Author:

Ksit BarbaraORCID,Szymczak-Graczyk AnnaORCID,Pilch Roman

Abstract

Current trends towards saving energy and designing sustainable buildings result in most designers focusing on achieving the best thermal parameters, thereby neglecting a careful moisture analysis. Excessive moisture content in building partitions degrades the mechanical properties of materials, reduces thermal insulation properties (which leads to an increase in the demand for thermal energy) and worsens the microclimate in rooms. Modern digital solutions help create appropriate models of partitions that work for many years in good environmental conditions. According to the analysis of air parameters, 1 m3 of air at 20 °C contains approx. 17.3 g of water. When the temperature of the air reaches the dew point temperature, water vapour condenses. The dew point depends on air temperature and relative air humidity; for instance, at the same air temperature of 20 °C, the dew point temperature at 40% relative air humidity is 6 °C, whereas at 90% relative humidity, it is over 18 °C. This means that the higher the value of relative humidity in the room at a certain temperature, the lower the temperature that will cause condensation. The article presents a numerical analysis of the insulation work of flexible materials within the layers of ventilated partitions in an 8-year simulated period of varying environmental conditions. The aim of the article is to analyze different models and variants of ventilated partition operation with respect to the advisability of using a vapour barrier to avoid the problem of destruction of thermal insulation and finishing layers of a ventilated roof.

Publisher

MDPI AG

Subject

General Materials Science

Reference73 articles.

1. Szymczak-Graczyk, A., Laks, I., Ksit, B., and Ratajczak, M. (2021). Analysis of the Impact of Omitted Accidental Actions and the Method of Land Use on the Number of Construction Disasters (a Case Study of Poland). Sustainability, 13.

2. Diagnostics and renovation of moisture affected historic buildings;Civ. Environ. Eng. Rep.,2022

3. Effect of temperature on water capillary rise coefficient of building materials;Build. Environ.,2016

4. Frössel, F. (2007). Osuszanie Murów i Renowacja Piwnic [Wall Drainage and Cellar Renovation], Polcen Sp. z o.o.

5. Intensity of damage in the aging process of buildings;Arch. Civ. Eng.,2020

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献