Design Validation of a Low-Cost EMG Sensor Compared to a Commercial-Based System for Measuring Muscle Activity and Fatigue

Author:

Bawa AnthonyORCID,Banitsas KonstantinosORCID

Abstract

Electromyography (EMG) sensors have been used for measuring muscle signals and for diagnosing neuromuscular disease. Available commercial EMG sensor are expensive and not easily available for individuals. The aim of the study is to validate our designed low-cost sensor against a well-known commercial system for measuring muscle activity and fatigue assessment. The evaluation of the designed system was done through a series of dynamic exercises performed by volunteers. Our low-cost EMG sensor and the commercially available system were placed on the vastus lateralis muscle to concurrently record the signal in a maximum voluntary contraction (MVC). The signal analysis was done using two validation indicators: Spearman’s correlation, and intra-class cross correlation on SPSS 26.0 version. For the muscle fatigue assessment, the root mean square (RMS), mean absolute value (MAV) and mean frequency (MNF) indicators were used. The results at the peak and mean level muscle contraction intensity were computed. The relative agreement for the two systems was excellent at peak level muscle contraction range (ICC 0.74–0.92), average 0.83 and mean level muscle contraction intensity range (ICC 0.65–0.85) with an average of 0.74. The Spearman’s correlation average was 0.76 with the range of (0.71–0.85) at peak level contraction, whiles the mean level contraction average was 0.71 at a range of (0.62–0.81). In determining muscle fatigue, the RMS and MAV showed increasing values in the time domain, while the MEF decreased in the frequency domain. Overall, the results indicated a good to excellent agreement of the two systems and confirmed the reliability of our design. The low-cost sensor also proved to be suitable for muscle fatigue assessment. Our designed system can therefore be implemented for rehabilitation, sports science, and ergonomics.

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference21 articles.

1. Work load and fatigue in repetitive arm elevations

2. Evaluation of the amplitude and frequency components of the surface EMG as an index of muscle fatigue

3. Surface EMG based muscle fatigue evaluation in biomechanics

4. Low-cost wireless surface EMG sensor using the MSP430 microcontroller;Beneteau;Proceedings of the 2014 6th European Embedded Design in Education and Research Conference (EDERC),2014

5. A low cost surface EMG sensor network for hand motion recognition;Wu;Proceedings of the 2018 IEEE 1st International Conference on Micro/Nano Sensors for AI, Healthcare, and Robotics (NSENS),2018

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3