Can Adding BMP2 Improve Outcomes in Patients Undergoing the SUPERhip Procedure?

Author:

Paley DrorORCID,Shannon Claire E.,Nogueira Monica,Chiari Catharina,Harris Matthew

Abstract

Congenital femoral deficiency (CFD) Paley type 1b is characterized by severe bony deformity of the upper femur, extra-articular contractures of the hip, and, delayed ossification of the femoral neck and/or subtrochanteric region. The Systematic Utilitarian Procedure for Extremity Reconstruction of the hip (SUPERhip) procedure for the correction of CFD deformities was developed in 1997. Initially, a non-fixed angle device (rush rod) was used for fixation. Late complications of persistent delayed ossification and recurrent varus deformity occurred. In order to reduce and treat such complications, fixation with a fixed angle device and the off-label use of BMP2 to induce ossification of the un-ossified femoral neck were employed. The purpose of this study is to determine if the use of a fixed angle device, and, BMP2 inserted into a drill hole in the cartilage of the femoral neck, decreases the incidence of these late complications. We retrospectively reviewed 72 SUPERhip procedures performed for Paley type 1b CFD between 1997 and 2012. Due to recurrent varus or persistent delayed ossification of the femoral neck, 34 revision SUPERhip procedures were performed. In total, 106 SUPERhip procedures were studied. Sixty-eight SUPERhips were performed using internal fixation without BMP2, while 38 SUPERhips were performed with both internal fixation and the addition of BMP2. Forty-one were performed using non-fixed angle internal fixation while 65 had fixed angle internal fixation. Fixed angle devices significantly reduced the incidence of recurrent varus compared with non-fixed angle devices. Inserting BMP2 in the femoral neck significantly reduced the incidence of persistent delayed ossification. Using only a fixed angle device but no BMP2 did not reduce the incidence of delayed ossification. The combination of both a fixed angle device and BMP2 reduced the incidence of recurrent coxa vara and persistent delayed ossification of the femoral neck. The SUPERhip procedure corrects the pathoanatomy of the proximal femur in CFD Paley type 1b but is associated with a very high risk of recurrence of coxa vara and persistence of femoral neck delayed ossification, unless, a fixed angle internal fixation device is used to prevent recurrent coxa vara and BMP2 is used to induce ossification of the femoral neck.

Publisher

MDPI AG

Subject

Pediatrics, Perinatology and Child Health

Reference22 articles.

1. Lengthening reconstruction surgery for congenital femoral deficiency;Paley,1998

2. SUPERhip and SUPERhip2 Procedures for Congenital Femoral Deficiency;Paley,2018

3. Congenital Femoral Deficiency Reconstruction and Lengthening Surgery;Paley,2016

4. Treatment of Congenital Femoral Deficiency;Paley,2015

5. Lengthening reconstruction surgery for congenital femoral deficiency;Paley,2014

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3