Extra Lateral Pin or Less Radiation? A Comparison of Two Different Pin Configurations in the Treatment of Supracondylar Humerus Fracture

Author:

Kaya Özgür1ORCID,Gencer Batuhan2ORCID,Çulcu Ahmet3ORCID,Doğan Özgür2

Affiliation:

1. Department of Orthopedics and Traumatology, Faculty of Medicine, Lokman Hekim University, Ankara 06000, Turkey

2. Department of Orthopedics and Traumatology, Ankara City Hospital, Ankara 06000, Turkey

3. Department of Orthopedics and Traumatology, Ministry of Health Yüksekova State Hospital, Hakkari 30110, Turkey

Abstract

Background: Closed reduction and percutaneous fixation are the most commonly used methods in the surgical treatment of supracondylar humerus fractures. The pin configuration changes stability and is still controversial. The aim of this study was to investigate the relationship between surgical duration and radiation dose/duration for different pinning fixations. Methods: A total of 48 patients with Gartland type 2, 3, and 4 supracondylar fractures of the humerus were randomized into two groups—2 lateral and 1 medial (2L1M) pin fixation (n = 26) and 1 lateral 1 medial (1L1M) pin fixation (n = 22). A primary assessment was performed regarding surgical duration, radiation duration, and radiation dose. A secondary assessment included clinical outcome, passive range of motion, radiographic measurements, Flynn’s criteria, and complications. Results: There were 26 patients in the first group (2L1M) and 22 patients in the second group (1L1M). There was no statistical difference between the groups regarding age, sex, type of fracture, or Flynn’s criteria. The overall mean surgical duration with 1L1M fixation (30.59 ± 8.72) was statistically lower (p = 0.001) when compared to the 2L1M Kirschner wire K-wire fixation (40.61 ± 8.25). The mean radiation duration was 0.76 ± 0.33 s in the 1L1M K-wire fixation and 1.68 ± 0.55 s in the 2L1M K-wire fixation. The mean radiation dose of the 2L1M K-wire fixation (2.45 ± 1.15 mGy) was higher than that of the 1L1M K-wire fixation (0.55 ± 0.43 mGy) (p = 0.000). Conclusions: The current study shows that although there is no difference between the clinical and radiological outcomes, radiation dose exposure is significantly lower for the 1L1M fixation method.

Publisher

MDPI AG

Subject

Pediatrics, Perinatology and Child Health

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3