Ultrasonography Causes Agitation and Pain Leading to Hemodynamic Disturbance in Neonates: A Prospective Observational Study

Author:

Dincer Emre1ORCID,Özer Hamza2ORCID,Topçuoğlu Sevilay1,Karatekin Güner1

Affiliation:

1. Department of Neonatology, University of Health Sciences, Zeynep Kamil Maternity and Children’s Research and Training Hospital, Op. Dr. Burhanettin Öncel Cad No. 10, Üsküdar, Istanbul 34668, Turkey

2. Department of Radiology, Bolu Abant İzzet Baysal University Medical Faculty, Bolu 14030, Turkey

Abstract

Background: Ultrasonography is widely used in neonatological practice and studies investigating the hemodynamic effects of various treatment protocols or clinical situations. On the other hand, pain causes changes in the cardiovascular system; so, in the case of ultrasonography leading to pain in neonates, it may cause hemodynamic alterations. In this prospective study, we evaluate whether ultrasonographic application causes pain and changes in the hemodynamic system. Methods: Newborns undergoing ultrasonographic examination were enrolled in the study. Vital signs, cerebral and mesenteric tissue oxygenation (StO2) levels, and middle cerebral artery (MCA) Doppler measurements were recorded, and NPASS scores were calculated before and after ultrasonography. Results: We enrolled 39 patients in the study. After ultrasonography, Neonatal Pain, Agitation, and Sedation Scale (NPASS) scores were significantly higher (p < 0.01), and all vital signs (heart rate, respiratory rate, SpO2, diastolic and systolic blood pressure; p = 0.03; p < 0.01, p < 0.01, p < 0.01, p = 0.02, p = 0.03, respectively) were altered. Cerebral (p = 0.008) and mesenteric (p = 0.039) StO2 levels were significantly lower in the whole study group, MCA end-diastolic velocity decreased (p = 0.02), and the resistive index (p = 0.03) increased in patients whose NPASS score was >7 after ultrasonography. Conclusions: This study is the first to show that ultrasonography may cause pain in newborn patients, and alters vital signs and hemodynamic parameters. Therefore, precautions should be taken to protect newborn babies from pain during ultrasound applications, as they are already exposed to many noxious stimuli. Furthermore, pain scores should be considered in studies using ultrasonography and evaluating hemodynamic parameters to increase the reliability of the studies.

Publisher

MDPI AG

Subject

Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3