The Effect of Incubator Cover on Newborn Vital Signs: The Design of Repeated Measurements in Two Separate Groups with No Control Group

Author:

Çetin Kenan1ORCID,Ekici Behice2ORCID

Affiliation:

1. Neonatal Intensive Care Unit, Siverek State Hospital, Şanlıurfa 63600, Türkiye

2. School of Nursing, Maltepe University, Istanbul 34857, Türkiye

Abstract

(1) Background: During their stays in neonatal intensive care units (NICU), newborns are exposed to many stimuli that disrupt their physiological indicators. The aim of this study was to investigate the impact of the light–dark cycle created with and without an incubator cover on the vital signs of term and preterm newborns. (2) Methods: A repeated measures design was used in the study utilizing two separate groups, without a control group. The study included 91 neonates hospitalized in a NICU (44 term and 47 preterm). With and without an incubator cover, the newborns’ vital signs (heart rate (HR), respiratory rate (RR), oxygen saturation (SpO2), and body temperature (BT)) were measured. Three separate measurements were taken. (3) Results: The mean age of the newborns was 37.0 weeks. There was no significant difference between the HR and RR medians of the term and preterms in the incubator undraped and clad measurements (p > 0.05). At the first measurement, the SpO2 medians of the incubator-covered term and preterms were significantly higher than those of the incubator-covered term and preterms (p = 0.001). (4) Conclusions: The vital signs of the neonates demonstrated variable responses in the measurements when their incubators were covered vs. when they were not covered. However, more research on the effect of the light-dark cycle on their vital signs is required.

Publisher

MDPI AG

Subject

Pediatrics, Perinatology and Child Health

Reference45 articles.

1. Individualized developmental care for high risk newborns in the NICU: A practice guideline;VandenBerg;Early Hum. Dev.,2007

2. Sound reduction management in the neonatal intensive care unit for preterm or very low birth weight infants;Almadhoob;Cochrane Database Syst. Rev.,2015

3. Newborn physiological responses to noise in the neonatal unit;Cardosoa;Braz. J. Otorhinolaryngo,2015

4. Noise in the neonatal ıntensive care unit: What does the evidence tell us?;Casavant;Adv. Neonatal Care,2017

5. Elevated sound levels in the neonatal ıntensive care unit what ıs causing the problem?;Mayhew;Adv. Neonatal Care,2022

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3