The Role of Antisiphon Devices in the Prevention of Central Ventricular Catheter Obliteration for Hydrocephalus: A 15-Years Institution’s Experience Retrospective Analysis

Author:

Panagopoulos Dimitrios,Strantzalis Georgios,Gavra Maro,Boviatsis Efstathios,Korfias Stefanos

Abstract

Shunt over-drainage in patients harboring a ventriculoperitoneal shunt constitutes one of the most devastating, and difficult to manage, side effects associated with this operation. Siphoning is one of the most important contributing factors that predispose to this complication. Based on the fact that the predisposing pathophysiologic mechanism is considerably multiplicated, amelioration of that adverse condition is considerably difficult to achieve. A lot of evidence suggests that the widespread utilization of gravitational valves or antisiphon devices is of utmost importance, in order to minimize or even avoid the occurrence of such complications. The recent literature data highlight that gravity-related, long-lasting shunt over-drainage consists of a momentous factor that could be considered one of the main culprits of central shunt failure. A lot of efforts have been performed, in order to design effective means that are aimed at annihilating siphoning. Our tenet was the investigation of the usefulness of the incorporation of an extra apparatus in the shunt system, capable of eliminating the impact of the siphoning effect, based on the experience that was gained by their long-term use in our institution. A retrospective analysis was performed, based on the data that were derived from our institution’s database, centered on patients to which an ASD was incorporated into their initial shunt device between 2006 and 2021. A combination of clinical, surgical, radiological findings, along with the relevant demographic characteristics of the patients were collected and analyzed. We attempted to compare the rates of shunt dysfunction, attributed to occlusion of the ventricular catheter, in a group of patients, before and after the incorporation of an anti-siphon device to all of them. A total number of 120 patients who have already been shunted due to hydrocephalus of different etiologies, were managed with the insertion of an ASD. These devices were inserted at different anatomical locations, which were located peripherally to the initially inserted valvular mechanism. The data that were collected from a subpopulation of 17 of these patients were subjected to a separate statistical analysis because they underwent a disproportionately large number of operations (i.e., >10-lifetime shunt revisions). These patients were studied separately as their medical records were complicated. The analysis of our records revealed that the secondary implementation of an ASD resulted in a decrease of the 1-year and 5-year central catheter dysfunction rates in all of our patients when compared with the relevant obstruction rates at the same time points prior to ASD insertion. According to our data, and in concordance with a lot of current literature reports, an ASD may offer a significant reduction in the obstruction rates that is related to the ventricular catheter of the shunt. These data could only be considered preliminary and need to be confirmed with prospective studies. Nevertheless, this study could be considered capable of providing supportive evidence that chronic shunt over-drainage is a crucial factor in the pathophysiology of shunt malfunction. Apart from that, it could provide pilot data that could be reviewed in order to organize further clinical and laboratory studies, aiming toward the assessment of optimal shunt valve systems that, along with ASD, resist siphoning.

Publisher

MDPI AG

Subject

Pediatrics, Perinatology and Child Health

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3