Lung Function of Children at Three Sites of Varying Ambient Air Pollution Levels in Uganda: A Cross Sectional Comparative Study

Author:

Kirenga Bruce,Nantanda Rebecca,de Jong Corina,Mugenyi Levicatus,Meng Qingyu,Aniku Gilbert,Williams Sian,Aanyu-Tukamuhebwa Hellen,Kamya Moses,Schwander Stephan,van der Molen Thys,Mohsenin VahidORCID

Abstract

Air pollution is a major cause of sub-optimal lung function and lung diseases in childhood and adulthood. In this study we compared the lung function (measured by spirometry) of 537 Ugandan children, mean age 11.1 years in sites with high (Kampala and Jinja) and low (Buwenge) ambient air pollution levels, based on the concentrations of particulate matter smaller than 2.5 micrometres in diameter (PM2.5). Factors associated with lung function were explored in a multiple linear regression model. PM2.5 level in Kampala, Jinja and Buwenge were 177.5 µg/m3, 96.3 µg/m3 and 31.4 µg/m3 respectively (p = 0.0000). Respectively mean forced vital capacity as % of predicted (FVC%), forced expiratory volume in one second as % of predicted (FEV1%) and forced expiratory flow 25–75% as % of predicted (FEF25–75%) of children in high ambient air pollution sites (Kampala and Jinja) vs. those in the low ambient air pollution site (Buwenge subcounty) were: FVC% (101.4%, vs. 104.0%, p = 0.043), FEV1% (93.9% vs. 98.0, p = 0.001) and FEF25–75% (87.8 vs. 94.0, p = 0.002). The proportions of children whose %predicted parameters were less than 80% predicted (abnormal) were higher among children living in high ambient air pollution than those living in lower low ambient air pollutions areas with the exception of FVC%; high vs. low: FEV1 < 80%, %predicted (12.0% vs. 5.3%, p = 0.021) and FEF25–75 < 80%, %predicted (37.7% vs. 29.3%, p = 0.052) Factors associated with lung function were (coefficient, p-value): FVC% urban residence (−3.87, p = 0.004), current cough (−2.65, p = 0.048), underweight (−6.62, p = 0.000), and overweight (11.15, p = 0.000); FEV1% underweight (−6.54, p = 0.000) and FEF25–75% urban residence (−8.67, p = 0.030) and exposure to biomass smoke (−7.48, p = 0.027). Children in study sites with high ambient air pollution had lower lung function than those in sites with low ambient air pollution. Urban residence, underweight, exposure to biomass smoke and cough were associated with lower lung function.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3