Abstract
The high concentration of ammonium (NH4+-N) and manganese (Mn2+) in underground water poses a major problem for drinking water treatment plants. Effective catalytic oxidative removal of NH4+-N and Mn2+ by iron-manganese co-oxide film (MeOx) filters was first developed by our group in a previous study. In this study, several identical pilot-scale filters were employed to optimize the start-up process for simultaneous removal of NH4+-N and Mn2+ from potable water supplies. Experiments were conducted to assess the influence of Mn2+ concentration, Fe2+ concentration, filtration rate and dosing time on the start-up period of the filter. Results demonstrated that the ability of the filter to remove completely 1.5 mg/L NH4+-N could be achieved on the sixth day at the soonest and the removal of Mn2+ could reach 1 mg/L by the 18th day. Filter R3 feeding with 1 mg/L Fe2+, 2 mg/L Mn2+ and 3.5 mg/L MnO4− during the start-up period exhibited the optimum NH4+-N and Mn2+ removal effect. Short dosing time was not conducive to attaining full NH4+-N removal in filters, especially the activity of NO2−-N conversion to NO3−-N. The compositional analysis and element distribution analysis results demonstrated that there was an abundance of C, O, Mn, Mg, Fe, Ca and Si across the entire area of the surface of the filter media and the elemental distribution was homogeneous, which was different from the biofilter media. Knowledge-guided performance optimization of the active iron-manganese co-oxide could pave the way for its future technological use.
Subject
Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献