Detailed One-Year Follow-Up in Left Bundle Branch Area Pacing: Echocardiography, Natriuretic Peptide, Electrical Parameters and Complications

Author:

Fularz Maciej1,Mitkowski Przemysław2

Affiliation:

1. Department of Cardiology, University of Zielona Góra, ul. Zyty 28, 65-046 Zielona Góra, Poland

2. 1st Department of Cardiology, Poznań University of Medical Sciences, ul. Długa 1/2, 61-848 Poznań, Poland

Abstract

Background: LBBAP is a promising method of cardiac pacing. Data on some follow-up details are still limited. We aimed to evaluate LBBAP over a one-year follow-up period. Methods: The studied population consisted of 110 patients who underwent LBBAP device implantation (93 for bradycardia indications, 17 for CRT). Echocardiography and NT-proBNP measurement were performed before the procedure and after one year. Electrical parameters, complications and some other conditions that required attention were noted during the observation period. Results: In total, 89 patients completed the one-year follow-up. NT-proBNP and echocardiographic parameters (LVEF, left ventricular end-diastolic dimension, left atrium dimension) improved after the one-year follow-up, especially in the patients with CRT indications, but also in the bradycardia patients. The independent predictors of a positive heart function response were higher baseline NT-proBNP and the presence of either RBBB or LBBB. The electrical parameters were satisfactory but a slight raise in the pacing threshold was observed at subsequent control visits. Major complications occurred in 4.5% of patients in the acute phase and in 4.4% during the follow-up (the most common was dislodgement of the non-LBBAP lead). One patient is presumed to have developed pacing-induced cardiomyopathy. The most frequent mild complications were intraprocedural RBBB (9.1%) and conversion to deep septal pacing during the follow-up period (5.5%). In addition, 4.4% of the patients required individual programming of the pacing output to maintain the optimal type of capture. Conclusions: The impact of LBBAP device implantation on cardiac function parameters is positive in a wide range of indications, especially in patients with RBBB or LBBB. The prevalence of complications is relatively high but major complications are rarely associated with LBBAP issues.

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3