A Ducted Photovoltaic Façade Unit with Forced Convection Cooling
-
Published:2022-10-09
Issue:19
Volume:14
Page:12875
-
ISSN:2071-1050
-
Container-title:Sustainability
-
language:en
-
Short-container-title:Sustainability
Author:
Elbakheit Abdel Rahman,
Waheeb SahlORCID,
Mahmoud Ahmed
Abstract
This paper explores the potential of forced convection cooling in a ducted photovoltaic façade unit. Where a photovoltaic panel is backed by a 5 cm thick insulated duct at a depth of 50 cm. The potential of heat removal from the photovoltaic unit due to forced convection is investigated with a range of fan speeds from 1 m/s to 6 m/s. It is found that the ΔT between the inlet and outlet of the duct ranged from 2.6–24.6 °C. A fan speed of 4 m/s yielded the highest cooling potential by removing 550 W with a cooling efficiency of 51%. Whereas a fan speed of 6 m/s yielded the lowest mean PV cell temperature of 62.7 °C. This would improve the cell’s efficiency by 17.53%. This very experimental setup has been tested previously with natural convection cooling, which removed 529 W with a maximum efficiency of 48.98% This improves PV panel efficiency by 12.69%. The addition of heat removed and power recovered by the ducted system was 68.53% of the former (i.e., forced convection), while it was 61.67% for the latter. A 12 V DC fan with a variable speed electric circuit powered by a fraction of the PV generated power (i.e., 0.75 W) yielded better cooling that translated into nearly 19 W of further energy generation.
Funder
the Deanship of Scientific Research at King Saud University
Subject
Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development,Building and Construction
Reference25 articles.
1. Urbanization and Development,2016
2. Bioclimatic Technology in High Rise Office Building Design: A Comparison Study for Indoor Environmental Condition;Lokman Hakim;J. Sci. Technol.,1970
3. Why Tall Buildings? The Potential of Sustainable Technologies in Tall Buildings;Elbakheit;Int. J. High-Rise Build.,2012
4. A FRAMEWORK TOWARDS ENHANCED SUSTAINABLE SYSTEMS INTEGRATION INTO TALL BUILDINGS DESIGN
5. Effect of duct width in ducted photovoltaic facades,2008
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献