Abstract
This paper is focused on analyzing, investigating, and designing a hybrid energy system based on sustainable or renewable resources, namely solar and wind energy, in addition to using a diesel generator and battery storage to supply a small resort in Suez, Egypt. The resort is located in Sokhna, which is on the Suez gulf and is about 50 km from the Suez governorate and 100 km from Cairo, Egypt. The Sokhna coast has plenty of high solar radiation and wind energy all year. At the same time, the Egyptian government is building many wind and photovoltaic projects there. Thus, it is expected that it will be very economic to use solar and wind energy in that area to supply the resort. The optimal combinations of energy resources to meet the load demand under various scenarios are considered. The optimal mix of sources is investigated with and without the presence of the grid. The cropped outcomes show that the hybrid energy system, which is also in the presence of the grid, is a very economical solution that provides the resort with an acceptable energy cost. The cost of energies (CoEs) is equal to 0.0441 and 0.0443 $/kWh for cases 2 and 4 (with grid), respectively. However, the CoEs are equal to 0.141 and 0.134 $/kWh for cases 1 and 3 (without grid), respectively.
Subject
Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development,Building and Construction
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献