Safety and Efficacy of a Single Procedure of Extraction and Reimplantation of Infected Cardiovascular Implantable Electronic Device (CIED) in Comparison with Deferral Timing: An Observational Retrospective Multicentric Study

Author:

Tascini Carlo12,Giuliano Simone2,Attanasio Vittorio3,Segreti Luca4,Ripoli Andrea5,Sbrana Francesco6ORCID,Severino Sergio7,Sordelli Chiara7,Weisz Sara Hana7ORCID,Zanus-Fortes Agnese2,Leanza Gabriele Maria2ORCID,Carannante Novella3,Di Cori Andrea4ORCID,Bongiorni Maria Grazia4,Zucchelli Giulio4,De Vivo Stefano8

Affiliation:

1. Infectious Diseases Clinic, Department of Medicine (DAME), University of Udine, 33100 Udine, Italy

2. Infectious Diseases Clinic, Azienda Sanitaria Universitaria del Friuli Centrale (ASUFC), 33100 Udine, Italy

3. First Division of Infectious Diseases, Cotugno Hospital, Azienda Ospedaliera Dei Colli, 80131 Napoli, Italy

4. Second Division of Cardiology, Cardiac-Thoracic and Vascular Department, University Hospital of Pisa, 56126 Pisa, Italy

5. Bioengineering Department, Fondazione Toscana Gabriele Monasterio, 56124 Pisa, Italy

6. Lipoapheresis Unit, Reference Center for Diagnosis and Treatment of Inherited Dyslipidemias, Fondazione Toscana “Gabriele Monasterio”, Via Moruzzi 1, 56124 Pisa, Italy

7. UOSD Cardiologia, Cotugno Hospital, Azienda Ospedaliera Dei Colli, 80131 Napoli, Italy

8. UOC di Elettrofisiologia, Studio e Terapia delle Aritmie, Monaldi Hospital, 80131 Napoli, Italy

Abstract

(1) Background: Infections are among the most frequent and life-threatening complications of cardiovascular implantable electronic device (CIED) implantation. The aim of this study is to compare the outcome and safety of a single-procedure device extraction and contralateral implantation versus the standard-of-care (SoC) two-stage replacement for infected CIEDs. (2) Methods: We retrospectively included 66 patients with CIED infections who were treated at two Italian hospitals. Of the 66 patients enrolled in the study, 27 underwent a single procedure, whereas 39 received SoC treatment. All patients were followed up for 12 months after the procedure. (3) Results: Considering those lost to follow-up, there were no differences in the mortality rates between the two cohorts, with survival rates of 81.5% in the single-procedure group and 84.6% in the SoC group (p = 0.075). (4) Conclusions: Single-procedure reimplantation associated with an active antibiofilm therapy may be a feasible and effective therapeutic option in CIED-dependent and frail patients. Further studies are warranted to define the best treatment regimen and strategies to select patients suitable for the single-procedure reimplantation.

Publisher

MDPI AG

Subject

Pharmacology (medical),Infectious Diseases,Microbiology (medical),General Pharmacology, Toxicology and Pharmaceutics,Biochemistry,Microbiology

Reference46 articles.

1. European Heart Rhythm Association (EHRA) international consensus document on how to prevent, diagnose, and treat cardiac implantable electronic device infections—Endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), the Latin American Heart Rhythm Society (LAHRS), International Society for Cardiovascular Infectious Diseases (ISCVID) and the European Society of Clinical Microbiology and Infectious Diseases (ESCMID) in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS);Traykov;EP Eur.,2020

2. 16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United States;Greenspon;J. Am. Coll. Cardiol.,2011

3. Forty-Year Trends in Cardiac Implantable Electronic Device Infective Endocarditis;Llopis;Open Forum. Infect. Dis.,2022

4. Treatment and Prevention of Cardiovascular Implantable Electronic Device (CIED) Infections;Phillips;CJC Open,2022

5. The 11th World Survey of Cardiac Pacing and Implantable Cardioverter-Defibrillators: Calendar Year 2009—A World Society of Arrhythmia’s Project: 2009 Survey Cardiac Pacemakers and Icds;Mond;Pacing Clin. Electrophysiol.,2011

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3