Fatigue and Fracture Resistance Testing of Polyether Ether Ketone (PEEK) Implant Abutments in an Ex Vivo Chewing Simulator Model

Author:

Saravi BabakORCID,Flohr Anselm,Patzelt Sebastian B.ORCID,Spies Benedikt C.ORCID,Hazard Derek,Kohal Ralf J.ORCID

Abstract

Polyether ether ketone (PEEK) has been introduced into implant dentistry as a viable alternative to current implant abutment materials. However, data on its physico-mechanical properties are still scarce. The present study sought to shed light on this topic utilizing an ex vivo chewing simulator model. A total of 48 titanium two-piece implants were allocated into three groups (n = 16 per group): (1) implants with PEEK abutments and an internal butt-joint connection (PBJ), (2) implants with PEEK abutments and an internal conical implant–abutment connection (PC), and (3) implants with zirconia abutments and an internal butt-joint connection (ZA). All abutments were restored with a non-precious metal alloy crown mimicking the upper right central incisor. A dynamic chewing simulation of half (n = 8) of the specimens per group was performed with 5 × 106 cycles and a load of 49 N at a frequency of 1.7 Hz with thermocycling between 5 and 55 °C. The other eight specimens served as unloaded controls. Surface roughness, implant–abutment connection microgaps (IACMs), and the titanium base–abutment interface microgaps (TAIMs) in the loaded groups were evaluated. Finally, a quasi-static loading test was performed in a universal testing machine with all samples to evaluate fracture resistance. Overall, 23 samples survived the artificial chewing process. One abutment screw fracture was observed in the PC group. The ZA group showed higher surface roughness values than PEEK abutments. Furthermore, ZA revealed lower TAIM values compared to PEEK abutments. Similarly, ZA was associated with lower IACM values compared to PBJ. Fracture loads/bending moments were 1018 N/704 N cm for PBJ, 966 N/676 N cm for PC, and 738 N/508 N cm for ZA, with no significant differences compared to the unloaded references. Artificial loading did not significantly affect fracture resistance of the examined materials. PEEK abutments were associated with better load-bearing properties than zirconia abutments, although they showed higher microgap values. PEEK abutments could, therefore, be feasible alternatives to zirconia abutments based on the present ex vivo findings resembling 20 years of clinical service.

Publisher

MDPI AG

Subject

General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3