Does Humeral Component Version Affect Range of Motion and Clinical Outcomes in Reverse Total Shoulder Arthroplasty? A Systematic Review

Author:

Jassim Shivan S.ORCID,Ernstbrunner LukasORCID,Ek Eugene T.ORCID

Abstract

Background: Prosthesis selection, design, and placement in reverse total shoulder arthroplasty (RTSA) affect post-operative results. The aim of this systematic review was to evaluate the influence of the humeral stem version and prosthesis design (inlay vs. onlay) on shoulder function following RTSA. Methods: A systematic review of the literature on post-operative range of motion (ROM) and functional scores following RTSA with specifically known humeral stem implantations was performed using MEDLINE, Pubmed, and Embase databases, and the Cochrane Library. Functional scores included were Constant scores (CSs) and/or American Shoulder and Elbow Surgeons (ASES) scores. The patients were organised into three separate groups based on the implanted version of their humeral stem: (1) less than 20° of retroversion, (2) 20° of retroversion, and (3) greater than 20° of retroversion. Results: Data from 14 studies and a total of 1221 shoulders were eligible for analysis. Patients with a humeral stem implanted at 20° of retroversion had similar post-operative mean ASES (75.8 points) and absolute CS (68.1 points) compared to the group with humeral stems implanted at less than 20° of retroversion (76 points and 62.5 points; p = 0.956 and p = 0.153) and those implanted at more than 20° of retroversion (73.3 points; p = 0.682). Subjects with humeral stem retroversion at greater than 20° tended towards greater active forward elevation and external rotation compared with the group at 20° of retroversion (p = 0.462) and those with less than 20° of retroversion (p = 0.192). Patients with an onlay-type RTSA showed statistically significantly higher mean post-operative internal rotation compared to patients with inlay-type RTSA designs (p = 0.048). Other functional scores and forward elevation results favoured the onlay-types, but greater external rotation was seen in inlay-type RTSA designs (p = 0.382). Conclusions: Humeral stem implantation in RTSA at 20° of retroversion and greater appears to be associated with higher post-operative outcome scores and a greater range of motion when compared with a retroversion of less than 20°. Within these studies, onlay-type RTSA designs were associated with greater forward elevation but less external rotation when compared to inlay-type designs. However, none of the differences in outcome scores and range of motion between the humeral version groups were statistically significant.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3