Evaluation of Novel Embroidered Textile-Electrodes Made from Hybrid Polyamide Conductive Threads for Surface EMG Sensing
Author:
Etana Bulcha Belay12ORCID, Malengier Benny1ORCID, Kwa Timothy3, Krishnamoorthy Janarthanan4ORCID, Langenhove Lieva Van1
Affiliation:
1. Department of Materials, Textiles and Chemical Engineering, Ghent University, 9000 Gent, Belgium 2. Jimma Institute of Technology (JiT), School of Materials Science and Engineering, Jimma University, Jimma P.O. Box 378, Ethiopia 3. Medtronic, 710 Medtronic Parkway Minneapolis, Minneapolis, MN 55432-5604, USA 4. Jimma Institute of Technology (JiT), School of Biomedical Engineering, Jimma University, Jimma P.O. Box 378, Ethiopia
Abstract
Recently, there has been an increase in the number of reports on textile-based dry electrodes that can detect biopotentials without the need for electrolytic gels. However, these textile electrodes have a higher electrode skin interface impedance due to the improper contact between the skin and the electrode, diminishing the reliability and repeatability of the sensor. To facilitate improved skin–electrode contact, the effects of load and holding contact pressure were monitored for an embroidered textile electrode composed of multifilament hybrid thread for its application as a surface electromyography (sEMG) sensor. The effect of the textile’s inter-electrode distance and double layering of embroidery that increases the density of the conductive threads were studied. Electrodes embroidered onto an elastic strap were wrapped around the forearm with a hook and loop fastener and tested for their performance. Time domain features such as the Root Mean Square (RMS), Average Rectified Value (ARV), and Signal to Noise Ratio (SNR) were quantitatively monitored in relation to the contact pressure and load. Experiments were performed in triplicates, and the sEMG signal characteristics were observed for various loads (0, 2, 4, and 6 kg) and holding contact pressures (5, 10, and 20 mmHg). sEMG signals recorded with textile electrodes were comparable in amplitude to those recorded using typical Ag/AgCl electrodes (28.45 dB recorded), while the signal-to-noise ratios were, 11.77, 19.60, 19.91, and 20.93 dB for the different loads, and 21.33, 23.34, and 17.45 dB for different holding pressures. The signal quality increased as the elastic strap was tightened further, but a pressure higher than 20 mmHg is not recommended because of the discomfort experienced by the subjects during data collection.
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Reference33 articles.
1. Albulbul, A. (2016). Evaluating Major Electrode Types for Idle Biological Signal Measurements for Modern Medical Technology. Bio-Eng., 3. 2. (2021, January 20). Designing and Evaluating a Wearable Semg Device for the Elderly. Proceedings of the 14th International Conference on ICT, Society and Human Beings (ICT 2021), the 18th International Conference Web Based Communities and Social Media (WBC 2021), Online. 3. Mamdiwar, S.D., R, A., Shakruwala, Z., Chadha, U., Srinivasan, K., and Chang, C.-Y. (2021). Recent Advances on IoT-Assisted Wearable Sensor Systems for Healthcare Monitoring. Biosensors, 11. 4. An Overview of Patient’s Health Status Monitoring System Based on Internet of Things (IoT);Kadhim;Wirel. Pers. Commun.,2020 5. Abdulmalek, S., Nasir, A., Jabbar, W.A., Almuhaya, M.A.M., Bairagi, A.K., Khan, M.A.-M., and Kee, S.-H. (2022). IoT-Based Healthcare-Monitoring System towards Improving Quality of Life: A Review. Healthcare, 10.
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|