Optimization of the Orifice Shape of Cooling Fan Units for High Flow Rate and Low-Level Noise in Outdoor Air Conditioning Units

Author:

Park Se Min,Ryu Seo-Yoon,Cheong CheolungORCID,Kim Jong WookORCID,Park Byung Il,Ahn Young-Chull,Oh Sai Kee

Abstract

Demand for air conditioners is steadily increasing due to global warming and improved living standards. The noise, as well as the performance of air conditioners, are recognized as one of the crucial factors that determine the air conditioners’ values. The performance and noise of the air conditioner are mostly determined by those of its outdoor unit, which in turn depend on those of the cooling fan unit. Therefore, a cooling fan unit of high-performance and low noise is essential for air-conditioner manufacturers and developers. In this paper, the flow performance and flow noise of the entire outdoor unit with an axial cooling fan in a split-type air-conditioner were investigated. First, a virtual fan tester constructed by using about 18 million grids is developed for highly resolved flow simulation. The unsteady Reynolds-Averaged Navier–Stokes equations are numerically solved by using finite-volume computational fluid dynamics techniques. To verify the validity of the numerical analysis, the predicted P–Q curve of the cooling fan in a full outdoor unit is compared with the measured one. There was an excellent agreement between the two curves. The further detailed analysis identifies the coherent vortex structures between the fan blade tip and fan orifice, which adversely affect the flow performance and causes flow noise. Based on this analysis, the optimization of fan orifice was carried out using the response surface method with three geometric parameters: inlet radius, neck length, and outlet angel of the orifice. The optimum layout for the high flow rate is proposed under the understanding that the increased flow rate can be converted to noise reduction. The additional computation using the proposed optimum orifice shows that the flow rate is increased by 4.6% at the operating point. Finally, the engineering sample was manufactured by using the optimum design, and the measured data confirmed that the flow rate were increased by 2.1%, the noise reduction was made by 2.8 dBA, and the power consumption is reduced by 4.0% at the operating rotational speed.

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3