Test of Broken Suspender Specimen and Equivalent Static Calculation Method for Half-Through and Through Concrete-Filled Steel Tubular Arch Bridges
-
Published:2022-11-16
Issue:22
Volume:12
Page:11619
-
ISSN:2076-3417
-
Container-title:Applied Sciences
-
language:en
-
Short-container-title:Applied Sciences
Author:
Chen Kangming,Luo Jianping,Wu Qingxiong,Wang Huanwei
Abstract
In response to the frequent collapse of main girders caused by the breakage of suspenders on half-through and through arch bridges, a test specimen has been designed and fabricated with a through concrete-filled steel tube (CFST) arch bridge as the engineering background. A new electromagnetic disconnect trigger is employed to realize the rapid suspender breakage in the test specimen. Dynamic response tests of the residual structure of the arch bridge after suspender failures employing the test specimen have been carried out. A finite element model accounting for the suspender breakage dynamic process has been constructed by implementing ANSYS/LS-DYNA, and the results of the test and finite element analysis are compared. In order to simplify the dynamic response calculation process of the residual structure after hanger failures, the dynamic coefficient is introduced, and an equivalent static calculation method (ESCM) considering the dynamic effect of the suspender fracture is presented. Eleven kinds of CFST standard arch bridges with different spans are constructed, the static and dynamic effects of the standard arch bridge with various dynamic coefficients are compared, and then their corresponding dynamic coefficients for various suspender fractures are determined. The obtained results reveal that the proposed electromagnetic suspender breakage trigger can realize the hanger fracturing within 0.1 s, which accurately simulates the fracture process of an actual bridge suspender, and the influence on the value of the dynamic coefficient can be ignored when the duration for suspender fracture is less than or equal to 0.15 s. The influence of suspender fracture on the displacement and stress of the longitudinal beam is more notable than those of the arch rib. In particular, the long suspender breakage has the highest influence on the displacement and stress of the longitudinal beam and arch rib. The fracture of the second short suspender has a remarkable impact on the suspender force of the adjacent hanger. When the ESCM is utilized to assess the mechanical behavior of the half-through and through CFST arch bridge, the dynamic coefficients of the longitudinal beam (suspender) were evaluated to be, conservatively, 1.8 (1.8) and 1.8 (1.7), respectively.
Funder
National Natural Science Foundation of China
National Key Research and Development Program of China
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Reference23 articles.
1. Effect of tensile overloads on fatigue crack growth of high strength steel wires;Mater. Des.,2013
2. Mechanical behavior of damaged strand suspender with asymmetric broken wires in arch bridges;J. Tongji Univ. (Nat. Sci.),2019
3. Robustness design of concrete-filled steel tube arch bridges;Bridge Constr.,2016
4. Huang, F.H. (2021). Vulnerability Analysis of Through Concrete-Filled Steel Tube Arch Bridge, Hefei University of Technology.