Abstract
The stator inter-turn short circuit fault is one of the most common and key faults in permanent magnet synchronous motor (PMSM). This paper introduces a time–frequency method for inter-turn fault detection in stator winding of PMSM using improved wavelet packet transform. Both stator current signal and vibration signal are used for the detection of short circuit faults. Two different experimental data from a three-phase PMSM were processed and analyzed by this time–frequency method in LabVIEW. The feasibility of this approach is shown by the experimental test.
Funder
National Natural Science Foundation
Subject
Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science
Cited by
45 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献