Mid-Term Clinical Outcomes and Hemodynamic Performances of Trifecta and Perimount Bioprostheses following Aortic Valve Replacement

Author:

Toto Francesca1ORCID,Leo Laura2,Klersy Catherine3ORCID,Torre Tiziano1,Theologou Thomas1,Pozzoli Alberto1,Caporali Elena2ORCID,Demertzis Stefanos14,Ferrari Enrico145ORCID

Affiliation:

1. Cardiac Surgery Unit, Cardiocentro Ticino Institute, EOC, 6900 Lugano, Switzerland

2. Department of Cardiology, Cardiocentro Ticino Institute, EOC, 6900 Lugano, Switzerland

3. Service of Clinical Epidemiology & Biometry, IRCCS Fondazione Policlinico San Matteo, 27100 Pavia, Italy

4. Biomedical Faculty, University of Italian Switzerland (USI), 6900 Lugano, Switzerland

5. School of Medicine, University of Zurich, 8006 Zurich, Switzerland

Abstract

Aims of the Study: We evaluated the clinical outcome and the hemodynamic and freedom from structural valve degeneration of two standard aortic bioprostheses. Methods: Clinical results, echocardiographic findings and follow-up data of patients operated for isolated or combined aortic valve replacement with the Perimount or the Trifecta bioprosthesis were prospectively collected, retrospectively analysed and compared. We weighted all the analyses by the inverse of the propensity of choosing either valves. Results: Between April 2015 and December 2019, 168 consecutive patients (all comers) underwent aortic valve replacement with Trifecta (n = 86) or Perimount (n = 82) bioprostheses. Mean age was 70.8 ± 8.6 and 68.8 ± 8.6 years for the Trifecta and Perimount groups, respectively (p = 0.120). Perimount patients presented a greater body mass index (27.6 ± 4.5 vs. 26.0 ± 4.2; p = 0.022), and 23% of them suffered from angina functional class 2–3 (23.2% vs. 5.8%; p = 0.002). Mean ejection fraction was 53.7 ± 11.9% (Trifecta) and 54.5 ± 10.4% (Perimount) (p = 0.994), with mean gradients of 40.4 ± 15.9 mmHg (Trifecta) and 42.3 ± 20.6 mmHg (Perimount) (p = 0.710). Mean EuroSCORE-II was 7 ± 11% and 6 ± 9% for the Trifecta and Perimount group, respectively (p = 0.553). Trifecta patients more often underwent isolated aortic valve replacement (45.3% vs. 26.8%; p = 0.016) and annulus enlargement (10.5% vs. 2.4%; p = 0.058). All-cause mortality at 30 days was 3.5% (Trifecta) and 8.5% (Perimount), (p = 0.203) while new pacemaker implantation (1.2% vs. 2.5%; p = 0.609) and stroke rate (1.2% vs. 2.5%; p = 0.609) were similar. Acute MACCE were observed in 5% (Trifecta) and 9% (Perimount) of patients with an unweighted OR of 2.22 (95%CI 0.64–7.66; p = 0.196) and a weighted OR of 1.10 (95%CI: 0.44–2.76, p = 0.836). Cumulative survival at 24 months was 98% (95%CI: 0.91–0.99) and 96% (95%CI: 0.85–0.99) for Trifecta and Perimount groups, respectively (log-rank test; p = 0.555). The 2-year freedom from MACCE was 94% (95%CI: 0.65–0.99) for Trifecta and 96% (95%CI: 0.86–0.99) for Perimount (log-rank test; p = 0.759, HR 1.46 (95%CI: 0.13–16.48)) in the unweighted analysis (not estimable in the weighted analysis). During the follow-up (median time: 384 vs. 593 days; p = 0.0001) there were no re-operations for structural valve degeneration. Mean valve gradient at discharge was lower for Trifecta across all valve sizes (7.9 ± 3.2 vs. 12.1 ± 4.7 mmHg; p < 0.001), but the difference did not persist during follow-up (8.2 ± 3.7 mmHg for Trifecta, 8.9 ± 3.6 mmHg for Perimount; p = 0.224); Conclusions: Postoperative outcome and mid-term follow-up were similar. An early better hemodynamic performance was detected for the Trifecta valve but did not persist over time. No difference in the reoperation rate for structural valve degeneration was found.

Publisher

MDPI AG

Subject

Pharmacology (medical),General Pharmacology, Toxicology and Pharmaceutics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3