Comparative Analysis of Riser Base and Flowline Gas Injection on Vertical Gas-Liquid Two-Phase Flow

Author:

Ahmed Salem K. Brini,Aliyu Aliyu M.ORCID,Baba Yahaya D.,Abdulkadir MukhtarORCID,Abdulhadi Rahil Omar,Lao LiyunORCID,Yeung Hoi

Abstract

Gas injection is a frequently used method for artificial lift and flow regime rectification in offshore production and transportation flowlines. The flow behaviour in such flowlines is complex and a better understanding of flow characteristics, such as flow patterns, void fraction/hold up distributions and pressure gradient is always required for efficient and optimal design of downstream handling facilities. Injection method and location have been shown to strongly affect downstream fluid behaviour that can have important implications for pumping and downstream facility design, especially if the development length between pipeline and downstream facility is less than L/D = 50 as reported by many investigators. In this article, we provide the results of an experimental investigation into the effects of the gas injection position on the characteristics of the downstream upwards vertical gas flow using a vertical riser with an internal diameter of 52 mm and a length of 10.5 m. A horizontal 40-m-long section connected at the bottom provides options for riser base or horizontal flow line injection of gas. The flowline gas injection is performed 40 m upstream of the riser base. A 16 by 16 capacitance wire mesh sensor and a gamma densitometer were used to measure the gas-liquid phase cross-sectional distribution at the riser top. A detailed analysis of the flow characteristics is carried out based on the measurements. These include flow regimes, cross-sectional liquid holdup distributions and peaking patterns as well as analysis of the time series data. Our findings show that flow behaviours differences due to different gas injection locations were persisting after a development length of 180D in the riser. More specifically, core-peaking liquid holdup occurred at the lower gas injection rates through the flowline, while wall-peaking holdup profiles were established at the same flow conditions for riser base injection. Wall peaking was associated with dispersed bubbly flows and hence non-pulsating as against core-peaking was associated with Taylor bubbles and slug flows. Furthermore, it was found that the riser base injection generally produced lower holdups. It was noted that the circumferential injector used at the riser base promoted high void fraction and hence low liquid holdups. Due to the bubbly flow structure, the slip velocity is smaller than for larger cap bubbles and hence the void fraction is higher. The measurements and observations presented in the paper provides valuable knowledge on riser base/flowline gas introduction that can directly feed into the design of downstream facilities such as storage tanks, slug catchers and separators.

Publisher

MDPI AG

Subject

Energy (miscellaneous),Energy Engineering and Power Technology,Renewable Energy, Sustainability and the Environment,Electrical and Electronic Engineering,Control and Optimization,Engineering (miscellaneous),Building and Construction

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3