Abstract
Introduction: This study aimed to verify the predictors of the diagnostic accuracy of rapid on-site evaluation (ROSE) in endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA) among patients with non-small cell lung cancer (NSCLC). Methods: We retrospectively reviewed consecutive patients with NSCLC who underwent EBUS-TBNA for staging or diagnosis at our hospital from June 2016 to June 2018. The patients were divided into two groups—those with a correct diagnosis and an incorrect diagnosis after ROSE. Kaplan–Meier plots and log-rank tests were used to estimate outcomes. Results: A total of 84 patients underwent EBUS-TBNA for staging and diagnosis. Sixty patients with demonstrated malignant mediastinal lymph nodes were enrolled. In the univariate analysis, lymph nodes < 1.5 cm (HR = 3.667, p = 0.031) and a SUVmax > 5 (HR = 41, p = 0.001) were statistically significant for diagnostic accuracy of ROSE. In the multivariate Cox regression analysis, only a SUVmax > 5 (HR = 20.258, p = 0.016) was statistically significant. Conclusions: A SUVmax > 5 is an independent predictor of higher diagnostic accuracy of ROSE in EBUS-TBNA in patients with NSCLC with malignant mediastinal lymph nodes. Therefore, ROSE in patients with a SUVmax < 5 might not be reliable and requires further prudent assessment (more shots or repeated biopsies at mediastinal LNs) in clinical practice.