Abstract
High frequency guided-waves offer a trade-off between the high sensitivity of local bulk ultrasonic thickness measurements and the large area scanning of lower frequency guided-waves, so it has been a growing interest for corrosion inspection with the dispersive SH1 mode. However, according to the dispersive curve, it is hard to generate the pure SH1 mode since the non-dispersive SH0 mode will be excited simultaneously. Thus, this paper investigates a transducer design method to generate a pure SH1 guided-wave, where the dual periodic-permanent-magnet electromagnetic acoustic transducers (PPM EMATs) are placed on exactly opposite positions either side of the plate symmetrically. The suppression effect for SH0 and the enhancement effect for SH1 of the dual PPM EMATs are mainly discussed by theoretical analysis and simulation analysis, and the influence of positioning errors of PPM EMATs placed on opposite sides of the plate on its performances are analyzed. Employing the proposed dual PPM EMATs, some experiments are performed to verify the reliability of finite element simulation. The results indicate that the dual PPM EMATs can suppress the SH0 mode and generate the pure SH1 mode effectively. Moreover, the longitudinal and lateral positioning errors can affect the dual PPM EMATs performances significantly.
Funder
National Natural Science Foundation of China
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Cited by
6 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献