Comparison of Manual versus Semi-Automatic Segmentations of the Stenotic Carotid Artery Bifurcation

Author:

Csippa BenjaminORCID,Mihály Zsuzsanna,Czinege Zsófia,Németh Márton Bence,Halász Gábor,Paál György,Sótonyi Péter

Abstract

Background: The image reconstruction of stenotic carotid bifurcation can be managed by medical practitioners and non-medical investigators with semi-automatic or manual segmentation. The outcome of blood flow simulations may vary because of a single mean voxel difference along the examined section, possibly more in the stenotic lesions, which can lead to conflicting results regarding other research findings. The aim of our project is computational geometry reconstruction for blood flow simulations to make it suitable for comparison with plaque image analysis performed by commercially available software. In this paper, a comparison is made between the manual and semi-automatic segmentations performed by non-medical and medical investigators, respectively. Methods: 30 patients were classified into three homogeneous groups. Our group classification was based on the following parameters: plaque calcification score, thickness, extent, remodeling and plaque localization. The images in the first group were segmented individually by medical practitioners and experienced non-medical investigators, the second group was segmented collectively, and the last group was segmented individually again. Cross-sections along the centerline were extracted, then geometrical and statistical analyses were performed. Exploratory flow simulations were carried out on two patients to showcase the effect of geometrical differences on the hemodynamic flow field. Results: The largest centerline-averaged voxel difference between the medical and non-medical investigators occurred in the first group with a positive difference of 1.16 voxels. In the second and third groups, the average voxel difference decreased to 0.65 and 0.75, respectively. The example case from the first group showed that the difference in maximum wall shear stress in the middle of the stenosis is 30% with an average voxel difference of 1.73. Meanwhile, it can decrease to 4% when the average voxel difference is 0.64 for the example case from the third group. Conclusions: A collective review of the medical images should preceded the manual segmentations before applying them in computational simulations in order to ensure a proper comparison with plaque image analysis. Especially complex pathology such as calcifications should be segmented under medical supervision or after specific training. Non-significant differences in the segmentation can lead to significant differences in the computed flow field.

Funder

Ministry of Innovation and Technology of Hungary from the National Research, Development and Innovation Fund

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3