Diagnostic Performance of Point-of-Care High-Sensitivity Troponin in the Exclusion of Non-ST-Elevation Myocardial Infarction in the Emergency Department

Author:

Zalama-Sánchez Daniel1,del Pozo Vegas Carlos23ORCID,Sanz-García Ancor456ORCID,de Santos-Castro Pedro Ángel3,Presencio-Dominguez Javier7,González-Izquierdo Pablo3,Sánchez-Ramón Susana7,Pinilla-Arribas Leyre Teresa3,Baladrón-Segura Manuel8,Cheayeb-Morán Jaldún3,Fernandez-García María8,Velasco de Cos Guillermo9ORCID,López-Izquierdo Raúl2710ORCID,Martín-Rodríguez Francisco211

Affiliation:

1. Emergency Department, Hospital Universitario Virgen de la Victoria, 29010 Málaga, Spain

2. Faculty of Medicine, University of Valladolid, 47002 Valladolid, Spain

3. Emergency Department, Hospital Clínico Universitario, 47003 Valladolid, Spain

4. Faculty of Health Sciences, University of Castilla la Mancha, 45600 Talavera de la Reina, Spain

5. Technological Innovation Applied to Health Research Group (ITAS Group), Faculty of Health Sciences, University of Castilla La Mancha, 45004 Toledo, Spain

6. Evaluación de Cuidados de Salud (ECUSAL), Instituto de Investigación Sanitaria de Castilla-La Mancha (IDISCAM), 45071 Toledo, Spain

7. Emergency Department, Hospital Universitario Rio Hortega, 47012 Valladolid, Spain

8. Clinical Analysis Department, Hospital Universitario Rio Hortega, 47012 Valladolid, Spain

9. Clinical Analysis Department, Hospital Clínico Universitario, 47003 Valladolid, Spain

10. CIBER of Respiratory Diseases (CIBERES), Institute of Health Carlos III, 28029 Madrid, Spain

11. Advanced Life Support, Emergency Medical Services (SACYL), 47007 Valladolid, Spain

Abstract

Background: This study evaluates the diagnostic performance of high-sensitivity troponin using point-of-care testing (POCT) devices compared with main laboratory measurements for ruling out non-ST-elevation myocardial infarction (NSTEMI) in emergency department (ED) patients presenting with non-traumatic chest pain. Methods: This multicenter, observational, prospective, non-interventional study was conducted in two Spanish hospitals from 1 June to 31 December 2023 and included adult patients presenting with non-traumatic chest pain admitted to the ED. High-sensitivity troponin levels were measured using both the Siemens Atellica® VTLi POCT device and main laboratory testing, with data collected on analytical results and measurement times. Results: Of the 201 patients who met the inclusion criteria, a significant correlation was observed between the POCT and laboratory assays. The area under the curve (AUC) of the ROC curve was consistently greater than 0.9, indicating a high diagnostic accuracy for ruling out NSTEMI. In addition, measurement times were significantly reduced using POCT compared to the core laboratory. Conclusion: These results suggest that high-sensitivity troponin POCT devices offer comparable diagnostic performance to traditional laboratory methods for the diagnosis of NSTEMI in the emergency department, potentially speeding up clinical decisions and optimizing resource utilization.

Funder

BIOTEC MEDICA

Publisher

MDPI AG

Reference26 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3