Abstract
Magnetic flux leakage (MFL) based on phase extraction for detecting the subsurface defects in ferromagnetic steel plate was investigated. The relationship between electromagnetic field phase and the subsurface defect was analyzed. Low-frequency alternating current (AC) excitation source and high-power magnetizer arrangement with Hall sensor were used to increase the skin depth of the MFL. Experiments results showed that 12 mm deep subsurface defect can be detected by using the phase extraction means, which is about two times higher than that by using the amplitude method.
Funder
National Key R&D Program of China
National Natural Science Foundation of China
National major scientific research instrument development project of Natural Science Foundation of China
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Cited by
3 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献