Abstract
In recent years, tissue engineering with mechanical stimulation has received considerable attention. In order to manipulate tissue samples, there is a need for electromechanical devices, such as constant-force actuators, with integrated deflection measurement. In this paper, we present an electrostatic constant-force actuator allowing the generation of a constant force and a simultaneous displacement measurement intended for tissue characterization. The system combines a comb drive structure and a constant-force spring system. A theoretical overview of both subsystems, as well as actual measurements of a demonstrator system, are provided. Based on the silicon-on-insulator technology, the fabrication process of a moveable system with an extending measurement tip is shown. Additionally, we compare measurement results with simulations. Our demonstrator reaches a constant-force of 79 ± 2 μN at an operating voltage of 25 V over a displacement range of approximately 40 μm, and the possibility of adjusting the constant-force by changing the voltage is demonstrated.
Subject
Control and Optimization,Control and Systems Engineering
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献