Indoor Microclimatic Conditions and Air Pollutant Concentrations in the Archaeological Museum of Abdera, Greece

Author:

Loupa Glykeria1ORCID,Dabanlis Georgios1ORCID,Resta Georgia1,Kostenidou Evangelia1,Rapsomanikis Spyridon2

Affiliation:

1. Laboratory of Atmospheric Pollution and Pollution Control Engineering of Atmospheric Pollutants, Department of Environmental Engineering, Faculty of Engineering, Democritus University of Thrace, P.O. Box 447, 67100 Xanthi, Greece

2. Unit of Environmental and Networking Technologies and Applications ATHENA-RIC, University Campus, Kimmeria, 67100 Xanthi, Greece

Abstract

Indoor microclimate conditions and air pollutant concentrations (O3, TVOC, CO, CO2, and particulate matter mass concentrations in six size bins) were measured in the Greek Archaeological Museum of Abdera, which houses priceless works of art from the birthplace of the ancient philosopher Democritus. The monitoring campaign took place during the spring and summer months, when there were the greatest number of visitors. In the exhibition rooms, daily variations in relative humidity ranged from 4% to 10%, and daily variations in air temperature ranged from 0.9 °C to 2.6 °C. These uncontrolled changes may endanger the housed antiquities. The microclimate in the storage rooms varied substantially less than in the exhibition halls due to dehumidifiers and the lack of visitors. Concerning air pollution, indoor O3 concentrations were higher than the recommended limit values for the conservation of artwork. Even more worrisome are particulate matter mass concentrations above the air quality guidelines. Despite the fact that the building is well insulated and that only artificial lighting is used in the exhibition halls, it is difficult to achieve adequate conditions for the protection of the works of art.

Publisher

MDPI AG

Reference43 articles.

1. Camuffo, D. (2019). Microclimate for Cultural Heritage: Measurement, Risk Assessment, Conservation, Restoration, and Maintenance of Indoor and Outdoor Monuments, Elsevier.

2. Indoor microclimate, ozone and nitrogen oxides in two medieval churches in Cyprus;Loupa;Atmos. Environ.,2006

3. Airborne particles, bacterial and fungal communities insights of two museum exhibition halls with diverse air quality characteristics;Saridaki;Aerobiologia,2023

4. Indoor air pollution: Effects on cultural and historic materials;Baer;Mus. Manag. Curatorship,1985

5. Thomson, G. (1978). The Museum Environment, Butterworths.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3