Comparison of Implant Surgery Methods of Cortical Tapping and Cortical Widening in Bone of Various Density: A Three-Dimensional Finite Element Study

Author:

Baek Yeon-Wha1,Lim Young-Jun2ORCID,Kim Bongju3ORCID

Affiliation:

1. Department of Prosthodontics, Gwanak Center, Seoul National University Dental Hospital, Seoul 08826, Republic of Korea

2. Department of Prosthodontics and Dental Research Institute, Seoul National University Dental Hospital, School of Dentistry, Seoul National University, Seoul 03080, Republic of Korea

3. Clinical Translational Research Center for Dental Science, Seoul National University Dental Hospital, Seoul 03080, Republic of Korea

Abstract

Purpose: The primary stability of a dental implant is critical for successful osseointegration during immediate loading. The cortical bone should be prepared to achieve enough primary stability, but not overcompressed. In this study, we investigated the stress and strain distribution in the bone around the implant induced by the occlusal force applied during immediate loading at various bone densities by the FEA method to compare cortical tapping and widening surgical techniques. Materials and Methods: A three-dimensional geometrical model of a dental implant and bone system was created. Five types of bone density combination (D111, D144, D414, D441 and D444) were designed. Two surgical methods—cortical tapping and cortical widening—were simulated in the model of the implant and bone. An axial load of 100 N and an oblique load of 30 N were applied to the crown. The maximal principal stress and strain were measured for comparative analysis of the two surgical methods. Results: Cortical tapping showed lower maximal stress of bone and maximal strain of bone than cortical widening when dense bone was located around the platform, regardless of the direction of the applied load. Conclusions: Within the limitations of this FEA study, it can be concluded that cortical tapping is biomechanically more advantageous to the implants under occlusal force during immediate loading, especially when the bone density around the platform is high.

Funder

South Korean government

Publisher

MDPI AG

Subject

General Materials Science

Reference38 articles.

1. Early loading of splinted implants supporting a two-unit fixed partial denture in the posterior maxilla: 13-month results from a randomized controlled clinical trial of two different implant systems;Ryu;Clin. Oral Implant. Res.,2016

2. Changes in stability after healing of immediately loaded dental implants;Simunek;Int. J. Oral Maxillofac. Implants,2010

3. Methods used to assess implant stability: Current status;Atsumi;Int. J. Oral Maxillofac. Implants,2007

4. Undersized Implant Site Preparation to Enhance Primary Implant Stability in Poor Bone Density: A Prospective Clinical Study;Alghamdi;J. Oral Maxillofac. Surg.,2011

5. Is surgical skill more important for clinical success than changes in implant hardware?;Albrektsson;Clin. Implant. Dent. Relat. Res.,2001

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Model of Dental Implant Cuff for Minimizing Stress Distribution Around Implant-Bone Interface: A 3-Dimensional Finite Element Analysis;2024 3rd International Conference on Computational Modelling, Simulation and Optimization (ICCMSO);2024-06-14

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3