Efficacy of Shock Wave-Enhanced Emission Photoacoustic Streaming (SWEEPS) in the Removal of Different Combinations of Sealers Used with Two Obturation Techniques: A Micro-CT Study

Author:

Baraba Anja1,Rajda Marko2ORCID,Baršić Gorana3,Jukić Krmek Silvana1ORCID,Šnjarić Damir4,Miletić Ivana1ORCID

Affiliation:

1. Department of Endodontics and Restorative Dentistry, School of Dental Medicine, University of Zagreb, 10000 Zagreb, Croatia

2. Dental Polyclinic Zagreb, Perkovčeva ul. 3, 10000 Zagreb, Croatia

3. Department of Quality, Faculty of Mechanical Engineering and Naval Architecture, Ivana Lučića 5, 10002 Zagreb, Croatia

4. Department of Endodontics and Restorative Dentistry, Faculty of Dental Medicine, University of Rijeka, 51000 Rijeka, Croatia

Abstract

This study sought to evaluate the efficacy of SWEEPS in the removal of epoxy-resin-based and calcium-silicate-containing endodontic sealer combined with single-cone and carrier-based obturation techniques through a micro-CT analysis. Seventy-six single-rooted extracted human teeth with single root canal were instrumented with Reciproc instruments. Specimens were randomly divided into four groups (n = 19) according to the root canal filling material and obturation technique: (1) AH Plus sealer + Reciproc gutta-percha, (2) TotalFill BC sealer + TotalFill BC Points, (3) AH Plus sealer + Guttafusion obturator, and (4) MTA Fillapex + Guttafusion obturator. All specimens were re-treated one week later using Reciproc instruments. Following re-treatment, root canals were additionally irrigated using the Auto SWEEPS modality. The differences in the root canal filling remnants were analyzed by micro-CT scanning of each tooth after root canal obturation, after re-treatment, and after additional SWEEPS treatment. Statistical analysis was performed using an analysis of variance (p < 0.05). The additional treatment with SWEEPS significantly reduced the volume of the root canal filling materials in all experimental groups compared to the removal of root canal filling using only reciprocating instruments (p < 0.05). However, the root canal filling was not removed completely from any of the samples. SWEEPS can be used to enhance the removal of both epoxy-resin-based and calcium-silicate-containing sealers, in combination with single-cone and carrier-based obturation techniques.

Funder

University of Zagreb

Publisher

MDPI AG

Subject

General Materials Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3