A Sliding Scale Signal Quality Metric of Photoplethysmography Applicable to Measuring Heart Rate across Clinical Contexts with Chest Mounting as a Case Study

Author:

McLean Marnie K.1ORCID,Weaver R. Glenn1ORCID,Lane Abbi1,Smith Michal T.1ORCID,Parker Hannah1ORCID,Stone Ben2,McAninch Jonas2,Matolak David W.2,Burkart Sarah1ORCID,Chandrashekhar M. V. S.2,Armstrong Bridget1ORCID

Affiliation:

1. Department of Exercise Science, University of South Carolina, Columbia, SC 29208, USA

2. College of Engineering and Computing, University of South Carolina, Columbia, SC 29208, USA

Abstract

Photoplethysmography (PPG) signal quality as a proxy for accuracy in heart rate (HR) measurement is useful in various public health contexts, ranging from short-term clinical diagnostics to free-living health behavior surveillance studies that inform public health policy. Each context has a different tolerance for acceptable signal quality, and it is reductive to expect a single threshold to meet the needs across all contexts. In this study, we propose two different metrics as sliding scales of PPG signal quality and assess their association with accuracy of HR measures compared to a ground truth electrocardiogram (ECG) measurement. Methods: We used two publicly available PPG datasets (BUT PPG and Troika) to test if our signal quality metrics could identify poor signal quality compared to gold standard visual inspection. To aid interpretation of the sliding scale metrics, we used ROC curves and Kappa values to calculate guideline cut points and evaluate agreement, respectively. We then used the Troika dataset and an original dataset of PPG data collected from the chest to examine the association between continuous metrics of signal quality and HR accuracy. PPG-based HR estimates were compared with reference HR estimates using the mean absolute error (MAE) and the root-mean-square error (RMSE). Point biserial correlations were used to examine the association between binary signal quality and HR error metrics (MAE and RMSE). Results: ROC analysis from the BUT PPG data revealed that the AUC was 0.758 (95% CI 0.624 to 0.892) for signal quality metrics of STD-width and 0.741 (95% CI 0.589 to 0.883) for self-consistency. There was a significant correlation between criterion poor signal quality and signal quality metrics in both Troika and originally collected data. Signal quality was highly correlated with HR accuracy (MAE and RMSE, respectively) between PPG and ground truth ECG. Conclusion: This proof-of-concept work demonstrates an effective approach for assessing signal quality and demonstrates the effect of poor signal quality on HR measurement. Our continuous signal quality metrics allow estimations of uncertainties in other emergent metrics, such as energy expenditure that relies on multiple independent biometrics. This open-source approach increases the availability and applicability of our work in public health settings.

Funder

National Institute of General Medical Sciences

National Institute of Diabetes and Digestive and Kidney Diseases

Publisher

MDPI AG

Subject

Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry

Reference49 articles.

1. Preclinical and clinical evaluation of autonomic function in humans;Joyner;J. Physiol.,2016

2. Association of Adverse Childhood Experiences with Cardiovascular Disease Later in Life: A Review;Godoy;JAMA Cardiol.,2021

3. Towards a continuous non-invasive cuffless blood pressure monitoring system using PPG: Systems and circuits review;Wang;IEEE Circuits Syst. Mag.,2018

4. A review on wearable photoplethysmography sensors and their potential future applications in health care;Castaneda;Int. J. Biosens. Bioelectron.,2018

5. Wearable devices for ambulatory cardiac monitoring: JACC state-of-the-art review;Sana;J. Am. Coll. Cardiol.,2020