Abstract
As a demountable structure, the structure with design for deconstruction (DfD) is considered as a key contribution on the promotion of current construction sustainability by directly reusing valuable components from old structures. As a preliminary study, this paper investigated the cyclic behavior of bolted joints consisting of three reinforced concrete blocks bolted by steel bolts under axial compressive, focusing on the damage and failure modes, resistance mechanism and stiffness development of the joints. Results showed that the number of steel bolts, the tightening process of the bolts and concrete compressive strength all had a significant effect on the overall performance and capacity of the joints. The failure mode of most of tested joints was considered as fracture of stirrups and steel bolts in the tested joints. According to the investigation of this study, several recommendations on the design of the joints were provided.
Subject
Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development
Reference47 articles.
1. Precast Concrete Structures;Elliott Kim,2016
2. A simplified analysis method for characterizing unbonded post-tensioned precast wall systems
3. Experimental Lateral Load Response of Unbonded Post-Tensioned Precast Concrete Walls;Perez;ACI Struct. J.,2013
4. Retrofit of Non-Ductile Moment-Resisting Frames Using Precast Infill Wall Panels
5. Design and Calculation of Joints in Assembly Plate Structures;Wan;Build. Struct.,1984
Cited by
27 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献