Abstract
The aim of the paper is based on a combined approach to improve dental alloy performance using a new Ni-free Co–Cr composition with Mo, Nb and Zr and coated with an anodic oxidation film. The coated and uncoated samples were surface characterized by performing SEM (scanning electronic microscopy), XRD (X-rays diffraction) contact angle measurements and corrosion studies with open circuit potential, potentiodynamic polarization and EIS (impedance electrochemical spectroscopy) procedures. The SEM equipment with an EDX (Energy-dispersive X-ray spectroscopy) module indicated the sample morphology and the XRD investigations established the formation of the oxides. The electrochemical procedures were performed in Ericsson artificial saliva for coated samples in various conditions. Based on all the experiments, including the decrease in the hydrophobic character of the uncoated samples and the decrease in the hydrophilic values of the anodized alloys, the improved performance of the coated samples was established as a conclusion.
Subject
General Materials Science,Metals and Alloys
Cited by
2 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献