Evaluation of a Polyester Filter and UV Light (PFUV) Dehumidifier to Improve Indoor Environmental Quality: Preliminary Results

Author:

Al-Rawi MohammadORCID,Farid Mohammed M.ORCID,Jones Rhys J.,Louie Ken

Abstract

Older residential dwellings in New Zealand frequently suffer from poor indoor environmental quality (IEQ) due to an ageing housing stock. Recent New Zealand surveys indicated around 50% of children live in houses that do not meet acceptable standards for thermal comfort. Children in these houses frequently experience respiratory conditions caused by dampness and mould during winter. New regulatory standards requiring a fixed heating source in the main living room of rental houses can increase rents and may result in the heating source not being utilized. This study evaluates an alternative low-cost portable air filter/sterilizer (PFUV) dehumidifier device for improving IEQ within the building envelope using Ultraviolet Germicidal Irradiation (UVGI) and a polyester filter (dual-10 30/30). This paper compares the effectiveness of the PFUV dehumidifier device and a conventional heat pump in terms of measured particulate matters as well as fungal profiles using Potato Dextrose Agar (PDA) plates. The PFUV dehumidifier successfully reduced the relative humidity to within a healthy range of (44–49%) compared to not running the device (54–60%), thereby reducing the suitability of the environment for mould growth. Additionally, the PFUV device achieved a reduction in average particulate matter (PM2.5) to within the range of 0.16 to 0.53 µg/m³ compared to the range of 1.06 to 2.42 µg/m³ before using the device.

Publisher

MDPI AG

Subject

Management, Monitoring, Policy and Law,Renewable Energy, Sustainability and the Environment,Geography, Planning and Development

Reference45 articles.

1. Keeping our Children Warm and Dry: Evidence from Growing Up in New Zealandhttps://www.branz.co.nz/pubs/research-reports/er58/

2. New Zealand Homes: Damp, Cold and Mouldyhttps://www.nzherald.co.nz/nz/new-zealand-homes-damp-cold-and-mouldy/Y6CTOSAHKKYUODIR27LJXGHDCA

3. House Condition Survey 2015 #2: Maintenance and Deferred Maintenance in New Zealand Houseshttps://www.branz.co.nz/pubs/research-now/hcs-2015/2-maintenance/

4. Ten questions concerning green buildings and indoor air quality

5. Indoor environmental quality in social housing: A literature review

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3