Abstract
Since aerosol continuously persists in dental settings, where different procedures and patients come in succession, the use of oronasal masks is highly recommended. Among them, respirators known as Filtering Face Pieces (FFP) show a protective superiority compared to surgical masks. Even concerning respirators classified as non-reusable, it is not known how many hours of use are necessary to compromise their filtering capacity. The aim of this study is to investigate the variations of filtering capacity of an FFP2 respirator over time, in order to safely optimize the timing of its use. Five respirators were worn by the same operator during clinical activity for different usage times (8, 16, 24, 32, 40 h), and one respirator was kept unused. All respirators underwent a bacterial filtration efficacy (BFE) test. T-test for paired data with Bootstrap technique and Wilcoxon test for paired data compared BFE values of the five tested FFP2s respectively at each time, and the areas with the corresponding values of the control respirator (FFp2-F). A generalized linear mixed effect model (GLM) was applied considering type of respirator and time as fixed effects and intercept as random effect. No significant statistical differences were present in the BFE of each time. Data obtained by the present study highlight the important ability of FFP2s to maintain their BFE over time, suggesting a long lasting protective function.
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献