Biomechanical Evaluation of a Novel Expandable Vertebral Augmentation System Using Human Cadaveric Vertebrae

Author:

Hsieh Ming-KaiORCID,Chen Wen-Jer,Lee Mel S.,Lin Sheng-Yu,Liu Mu-Yi,Lee De-MeiORCID,Tai Ching-LungORCID

Abstract

Unacceptable sagittal alignment and cement leakage are major concerns of percutaneous vertebroplasty when treating patients with painful vertebral osteoporotic compression fractures. To maintain the restored vertebral height and reduce the reliance on cement as the major stabilizer, an expandable vertebral augment system (EVA®) made of titanium alloy consisting of a rigid tube encased by a barrel with an anterior expansion mechanism was developed. The aim of the current study was to determine whether this novel design is as effective as existing procedures in terms of height restoration and biomechanical performance. Eight osteoporotic vertebrae (T12-L3) confirmed by dual-energy X-ray absorptiometry from two fresh-frozen human cadavers (70- and 72-year-old females) were used. Twenty-five percent reduced anterior wedge vertebral compression fractures were created using a material testing machine. Four randomized specimens were augmented with EVA® (Chang Gu Biotechnology Co. Ltd., Taipei city, Taiwan), and another four randomized specimens were augmented with OsseoFix® (AlphaTec Spine Inc., Carlsbad, CA, USA). The implant size and cement volume were controlled. The anterior vertebral body height (VBH) ratio and pre/postaugmented ultimate strength and stiffness were measured and compared. The mean anterior VBH restoration ratio was 8.54% in the EVA® group and 8.26% in the OsseoFix® groups. A significant difference from augmentation was measured in both groups (p < 0.05), but there was no significant difference between the EVA® and OsseoFix® groups in anterior VBH restoration. The ultimate strengths of the EVA® and OsseoFix® groups were 6071.4 ± 352.6 N and 6262.9 ± 529.2 N, respectively, both of which were statistically significantly higher than that of the intact group (4589.9 ± 474.6 N) (p < 0.05). The stiffnesses of the EVA®, OsseoFix®, and intact groups were 1087.2 ± 176.9, 1154.9 ± 168.9, and 1637.3 ± 340.8 N/mm, respectively, indicating that the stiffness was significantly higher in the intact group than in both the EVA® and OsseoFix® groups (p < 0.05). No significant differences were observed between the two augmentation procedures in height restoration or ultimate strength and stiffness. This novel EVA® system showed comparable height restoration and biomechanical performance to those of existing implants for human cadaveric osteoporotic compression fractures. Potential advantages of preventing cement posterior leakage and promoting cement interdigitation are expected with this ameliorated design.

Funder

Ministry of Science and Technology, Taiwan

Publisher

MDPI AG

Subject

Fluid Flow and Transfer Processes,Computer Science Applications,Process Chemistry and Technology,General Engineering,Instrumentation,General Materials Science

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3