Operating Theatre Ventilation Systems and Their Performance in Contamination Control: “At Rest” and “In Operation” Particle and Microbial Measurements Made in an Italian Large and Multi-Year Inspection Campaign

Author:

Romano Francesco,Milani Samanta,Ricci Roberto,Joppolo Cesare Maria

Abstract

In Operating Theatres (OT), the ventilation system plays an important role in controlling airborne contamination and reducing the risks of Surgical Site Infections (SSIs). The air cleanliness is really crucial in this field and different measurements are used in order to characterize the situation in terms of both airborne microbiological pollutants and particle size and concentration. Although the ventilation systems and airborne contamination are strictly linked, different air diffusion schemes (in particular, the Partial Unidirectional Airflow, P-UDAF, and the Mixing Airflow, MAF) and various design parameters are used, and there is still no consensus on real performance and optimum solutions. This study presents measurements procedures and results obtained during Inspection and Periodic Performance Testing (1228 observations) in a large sample of Italian OTs (175 OTs in 31 Italian hospitals) in their operative life (period from 2010 to 2018). The inspections were made after a cleaning procedure, both in “at-rest” conditions and “in operation” state. Inert and microbial contamination data (in air and on surfaces) are analyzed and commented according to four relevant air diffusion schemes and design classes. Related data on Recovery Time (RT) and personnel presence were picked up and are commented. The results confirm that the ventilation systems are able to maintain the targeted performance levels in the OT operative life. However, they attest that significant differences in real OT contamination control capabilities do exist and could be ascribed to various design choices and to different operation and maintenance practices. The study shows and confirms that the air diffusion scheme and the design airflow rate are critical factors. Beside large variations in measurements, the performance values, in terms of control of airborne particle and microbial contamination (in air and on surfaces), for P-UDAF systems are better than those that were assessed for the MAF air diffusion solution. The average performances do increase with increasing airflows, and the results offer a better insight on this relationship leading to some possible optimization.

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Reference53 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3