Distal Displacement of Maxillary Sinus Anterior Wall Versus Conventional Sinus Lift with Lateral Access: A 3-Year Retrospective Computerized Tomography Study

Author:

Menchini-Fabris Giovanni Battista,Toti Paolo,Crespi Giovanni,Covani Ugo,Crespi Roberto

Abstract

Background: The present study is designed to compare the outcomes of two sinus augmentation procedures: distal displacement of the anterior wall versus standard sinus lifting and grafting with a lateral window approach. Methods: In the displacement group, a localized surgical fracture of the sinus floor achieved through an electromagnetic device results in the distal displacement of the anterior wall. In the filling group, sinus lifting (with lateral access) and grafting with particulate xenogeneic bone substitute was performed. Bone volume beneath the maxillary sinus was investigated with computerized tomography after baseline and postoperative data superimposition. Clinical and radiological outcomes over three years had been evaluated. Results: Forty-three dental implants were selected. The two sinus lift procedures significantly increased the bone volume (p-value ≤ 0.0017) in the displacement group from 1.17 ± 0.34 to 1.53 ± 0.39 cc, with a final bone gain of +0.36 ± 0.17 cc, and in the filling group from 1.24 ± 0.41 to 1.94 ± 0.68 cc, with a bone augmentation of +0.71 ± 0.31 cc. No events of dental implant bulging into the maxillary sinus occurred. Two implants failed early on in the filling group, attesting the 3-year survival rate of 92.6% (CI95%: 82.7–100%). Marginal bone loss at the distal aspect was 1.66 ± 0.72 and 1.25 ± 0.78 mm, respectively, for the displacement and filling groups, with a significant difference (p-value = 0.0497). Conclusion: Results showed a significant and effective bone gain around dental implants at a 3-year survey for both sinus augmented by backward displacement of the anterior wall (+34%) and sinus lifting and grafting with a lateral window approach (+57%).

Publisher

MDPI AG

Subject

Health, Toxicology and Mutagenesis,Public Health, Environmental and Occupational Health

Reference40 articles.

1. Maxillary Sinus Septa and Anatomic Correlation With the Schneiderian Membrane

2. An economic evaluation of different sinus lift techniques

3. Schneider Membrane Elevation in Presence of Sinus Septa: Anatomic Features and Surgical Management

4. Augmentation of the sinus floor with mandibular bone block and simultaneous implantation: A 6-year clinical investigation;Khoury;Int. J. Oral Maxillofac. Implant.,1999

5. Grafting of the maxillary sinus floor with autogenous marrow and bone;Boyne;J. Oral Surg.,1980