Effects of Dielectric Barrier on Water Activation and Phosphorus Compound Digestion in Gas–Liquid Discharges

Author:

Lee Ye Rin1,Kim Do Yeob2ORCID,Kim Jae Young1ORCID,Lee Da Hye1,Bae Gyu Tae1,Jang Hyojun1,Park Joo Young3ORCID,Jung Sunghoon3,Jung Eun Young14ORCID,Park Choon-Sang5,Lee Hyung-Kun2ORCID,Tae Heung-Sik1

Affiliation:

1. School of Electronic and Electrical Engineering, College of IT Engineering, Kyungpook National University, Daegu 41566, Republic of Korea

2. Superintelligence Creative Research Laboratory, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Republic of Korea

3. Department of Nano-Bio Convergence, Korea Institute of Materials Science, Changwon 51508, Republic of Korea

4. The Institute of Electronic Technology, College of IT Engineering, Kyungpook National University, Daegu 41566, Republic of Korea

5. Department of Electrical Engineering, Milligan University, Johnson City, TN 37682, USA

Abstract

To generate a stable and effective air–liquid discharge in an open atmosphere, we investigated the effect of the dielectric barrier on the discharge between the pin electrode and liquid surface in an atmospheric-pressure plasma reactor. The atmospheric-pressure plasma reactor used in this study was based on a pin–plate discharge structure, and a metal wire was used as a pin-type power electrode. A plate-type ground electrode was placed above and below the vessel to compare the pin–liquid discharge and pin–liquid barrier discharge (PLBD). The results indicated that the PLBD configuration utilizing the bottom of the vessel as a dielectric barrier outperformed the pin–liquid setup in terms of the discharge stability and that the concentration of reactive species was different in the two plasma modes. PLBD can be used as a digestion technique for determining the phosphorus concentration in natural water sources. The method for decomposing phosphorus compounds by employing PLBD exhibited excellent decomposition performance, similar to the performance of thermochemical digestion—an established conventional method for phosphorus detection in water. The PLBD structure can replace the conventional chemical-agent-based digestion method for determining the total dissolved phosphorus concentration using the ascorbic acid reduction method.

Funder

ICT R&D program of MSIT/IITP

National Research Foundation (NRF) of Korea

Publisher

MDPI AG

Subject

General Materials Science,General Chemical Engineering