Validation of Noninvasive Assessment of Pulmonary Gas Exchange in Patients with Chronic Obstructive Pulmonary Disease during Initial Exposure to High Altitude

Author:

Champigneulle Benoit12ORCID,Reinhard Lukas345,Mademilov Maamed456,Marillier Mathieu1,Ulrich Tanja345,Carta Arcangelo345ORCID,Scheiwiller Philipp345,Shabykeeva Saltanat456,Sheraliev Ulan456,Abdraeva Ainura456,Magdieva Kamila456,Mirzalieva Gulzada456,Taalaibekova Aijan456,Ozonova Aigul456,Erkinbaeva Aidai456,Shakiev Nurdin456,Azizbekov Syimyk456,Ainslie Philip7,Sooronbaev Talant456,Ulrich Silvia345ORCID,Bloch Konrad345ORCID,Verges Samuel1ORCID,Furian Michael1345ORCID

Affiliation:

1. HP2 Laboratory, INSERM U1300, Grenoble Alpes University, CHU Grenoble Alpes, 38400 Grenoble, France

2. Department of Anesthesia and Critical Care, Grenoble Alpes University Hospital, 38043 Grenoble, France

3. Department of Pulmonology, University Hospital Zürich, 8091 Zurich, Switzerland

4. Swiss-Kyrgyz High-Altitude Medicine and Research Initiative, 8091 Zurich, Switzerland

5. Swiss-Kyrgyz High-Altitude Medicine and Research Initiative, Bishkek 720040, Kyrgyzstan

6. Department of Respiratory Medicine, National Center for Cardiology and Internal Medicine, Bishkek 720040, Kyrgyzstan

7. Centre for Heart, Lung and Vascular Health, School of Health and Exercise Sciences, University of British Columbia Okanagan, Kelowna, BC V1V 1V7, Canada

Abstract

Investigation of pulmonary gas exchange efficacy usually requires arterial blood gas analysis (aBGA) to determine arterial partial pressure of oxygen (mPaO2) and compute the Riley alveolar-to-arterial oxygen difference (A-aDO2); that is a demanding and invasive procedure. A noninvasive approach (AGM100), allowing the calculation of PaO2 (cPaO2) derived from pulse oximetry (SpO2), has been developed, but this has not been validated in a large cohort of chronic obstructive pulmonary disease (COPD) patients. Our aim was to conduct a validation study of the AG100 in hypoxemic moderate-to-severe COPD. Concurrent measurements of cPaO2 (AGM100) and mPaO2 (EPOC, portable aBGA device) were performed in 131 moderate-to-severe COPD patients (mean ±SD FEV1: 60 ± 10% of predicted value) and low-altitude residents, becoming hypoxemic (i.e., SpO2 < 94%) during a short stay at 3100 m (Too-Ashu, Kyrgyzstan). Agreements between cPaO2 (AGM100) and mPaO2 (EPOC) and between the O2-deficit (calculated as the difference between end-tidal pressure of O2 and cPaO2 by the AGM100) and Riley A-aDO2 were assessed. Mean bias (±SD) between cPaO2 and mPaO2 was 2.0 ± 4.6 mmHg (95% Confidence Interval (CI): 1.2 to 2.8 mmHg) with 95% limits of agreement (LoA): −7.1 to 11.1 mmHg. In multivariable analysis, larger body mass index (p = 0.046), an increase in SpO2 (p < 0.001), and an increase in PaCO2-PETCO2 difference (p < 0.001) were associated with imprecision (i.e., the discrepancy between cPaO2 and mPaO2). The positive predictive value of cPaO2 to detect severe hypoxemia (i.e., PaO2 ≤ 55 mmHg) was 0.94 (95% CI: 0.87 to 0.98) with a positive likelihood ratio of 3.77 (95% CI: 1.71 to 8.33). The mean bias between O2-deficit and A-aDO2 was 6.2 ± 5.5 mmHg (95% CI: 5.3 to 7.2 mmHg; 95%LoA: −4.5 to 17.0 mmHg). AGM100 provided an accurate estimate of PaO2 in hypoxemic patients with COPD, but the precision for individual values was modest. This device is promising for noninvasive assessment of pulmonary gas exchange efficacy in COPD patients.

Funder

French National Research Agency

Swiss National Science Foundation

Fonds de dotation AGIR pour les maladies chroniques

Grenoble Alpes University foundation

Publisher

MDPI AG

Subject

General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3