Effects of Earmuffs and Eye Masks on Propofol Sedation during Spinal Anesthesia for Orthopedic Surgery: A Randomized Controlled Trial

Author:

Park Jin-Woo12ORCID,Bae Sung Il3,Ryu Jungyul4,Chung Seung Hyun5,Do Sang-Hwan12

Affiliation:

1. Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam 13620, Republic of Korea

2. Department of Anesthesiology and Pain Medicine, College of Medicine, Seoul National University, Seoul 03080, Republic of Korea

3. Department of Anesthesiology and Pain Medicine, Jinju Gyeongsang National University Hospital, Jinju 52727, Republic of Korea

4. Department of Anesthesiology and Pain Medicine, Hallym University Dongtan Sacred Heart Hospital, Hwaseong 18450, Republic of Korea

5. Department of Anesthesiology and Pain Medicine, Uijeongbu Eulji Medical Center, Eulji University, Uijeongbu 11759, Republic of Korea

Abstract

Intravenous sedative drugs are commonly administered during regional anesthesia. However, reducing the excessive use of sedatives while providing adequate sedation is important from the clinical perspective, since the use of sedatives can cause considerable complications. We hypothesized that the application of earmuffs and eye masks would help reduce the sedative dose required to maintain proper sedation by blocking external stimuli. Patients who underwent orthopedic surgery under spinal anesthesia were randomly allocated to the control (no intervention) or intervention group (wearing earmuffs and eye masks). Intravenous sedation was administered using target-controlled infusion of propofol. The target concentration was controlled to maintain a Modified Observer’s Assessment of Alertness and Sedation score of 3 or 4. The primary outcome was the intraoperative propofol requirement. We also investigated the incidence of apnea, and patient satisfaction. Propofol requirement was significantly lower in the intervention group than that in the control group (2.3 (2.0–2.7) vs. 3.1 (2.7–3.4) mg·kg−1·h−1; p < 0.001). Intraoperative apnea occurred less frequently (p = 0.038) and patient satisfaction was higher (p = 0.002) in the intervention group compared to the control group. This study demonstrated that the use of earmuffs and eye masks during sedation was associated with lower propofol requirement and improved sedation quality.

Publisher

MDPI AG

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3