Abstract
A knee exoskeleton with an adaptive instantaneous rotation center and impact absorption is used for rehabilitation. Due to the human knee joint’s special physiological structure and motion characteristics, the exoskeleton mechanism needs to be designed for both static and dynamic aspects. Therefore, a novel knee exoskeleton mechanism was designed. To adapt to the rotation center of the knee joint, a mechanism with cross-configuration was designed according to the equivalent degree of freedom and the stiffness of the springs was calculated by its combination with gait motion, so that the average force of the human body was minimized. A dynamic model of the exoskeleton was established. To overcome the uncertainty in the parameters of the human and robotic limbs, an adaptive controller was designed and a Lyapunov stability analysis was conducted to verify the system. A simulation was conducted and experimental results show that the tracking error of the knee joint angle between the actual and desired trajectory was within the range of −1 to 1 degree and indicate the effectiveness of the controller.
Funder
National Natural Science Foundation of China
Subject
Electrical and Electronic Engineering,Biochemistry,Instrumentation,Atomic and Molecular Physics, and Optics,Analytical Chemistry
Cited by
3 articles.
订阅此论文施引文献