Automated Opportunistic Trabecular Volumetric Bone Mineral Density Extraction Outperforms Manual Measurements for the Prediction of Vertebral Fractures in Routine CT

Author:

Goller Sophia S.1ORCID,Rischewski Jon F.2ORCID,Liebig Thomas2,Ricke Jens1,Siller Sebastian3ORCID,Schmidt Vanessa F.1ORCID,Stahl Robert2ORCID,Kulozik Julian4,Baum Thomas5ORCID,Kirschke Jan S.5ORCID,Foreman Sarah C.6ORCID,Gersing Alexandra S.2

Affiliation:

1. Department of Radiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany

2. Institute for Diagnostic and Interventional Neuroradiology, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany

3. Department of Neurosurgery, University Hospital, LMU Munich, Marchioninistr. 15, 81377 Munich, Germany

4. Institute of Micro Technology and Medical Device Technology (MIMED), Technical University of Munich, Boltzmannstr. 15, 85748 Garching, Germany

5. Department of Diagnostic and Interventional Neuroradiology, Klinikum Rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany

6. Department of Diagnostic and Interventional Radiology, Klinikum Rechts der Isar, Technical University of Munich, Ismaninger Str. 22, 81675 Munich, Germany

Abstract

Opportunistic osteoporosis screening using multidetector CT-scans (MDCT) and convolutional neural network (CNN)-derived segmentations of the spine to generate volumetric bone mineral density (vBMD) bears the potential to improve incidental osteoporotic vertebral fracture (VF) prediction. However, the performance compared to the established manual opportunistic vBMD measures remains unclear. Hence, we investigated patients with a routine MDCT of the spine who had developed a new osteoporotic incidental VF and frequency matched to patients without incidental VFs as assessed on follow-up MDCT images after 1.5 years. Automated vBMD was generated using CNN-generated segmentation masks and asynchronous calibration. Additionally, manual vBMD was sampled by two radiologists. Automated vBMD measurements in patients with incidental VFs at 1.5-years follow-up (n = 53) were significantly lower compared to patients without incidental VFs (n = 104) (83.6 ± 29.4 mg/cm3 vs. 102.1 ± 27.7 mg/cm3, p < 0.001). This comparison was not significant for manually assessed vBMD (99.2 ± 37.6 mg/cm3 vs. 107.9 ± 33.9 mg/cm3, p = 0.30). When adjusting for age and sex, both automated and manual vBMD measurements were significantly associated with incidental VFs at 1.5-year follow-up, however, the associations were stronger for automated measurements (β = −0.32; 95% confidence interval (CI): −20.10, 4.35; p < 0.001) compared to manual measurements (β = −0.15; 95% CI: −11.16, 5.16; p < 0.03). In conclusion, automated opportunistic measurements are feasible and can be useful for bone mineral density assessment in clinical routine.

Funder

German Society of Musculoskeletal Radiology

Munich Clinician Scientist Program (MCSP) of the University of Munich

German Research Foundation

European Research Council

Publisher

MDPI AG

Subject

Clinical Biochemistry

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3