Abstract

This study aimed to compare the accuracy of real-time trans-tracheal ultrasound (TTUS) with capnography to confirm intubation in cardiopulmonary resuscitation (CPR) while wearing a powered air-purifying respirator (PAPR). This setting reflects increased caution due to contagious diseases. This single-center, prospective, comparative study enrolled patients requiring CPR while wearing a PAPR who visited the emergency department of a tertiary medical center from December 2020 to August 2022. A physician performed the TTUS in real time and recorded the tube placement assessment. Another healthcare provider attached waveform capnography to the tube and recorded end-tidal carbon dioxide (EtCO2) after five ventilations. The accuracy and agreement of both methods compared with direct laryngoscopic visualization of tube placement, and the time taken by both methods was evaluated. Thirty-three patients with cardiac arrest were analyzed. TTUS confirmed tube placement with 100% accuracy, sensitivity, and specificity, whereas capnography demonstrated 97% accuracy, 96.8% sensitivity, and 100% specificity. The Kappa values for TTUS and capnography compared to direct visualization were 1.0 and 0.7843, respectively. EtCO2 was measured in 45 (37–59) seconds (median (interquartile range)), whereas TTUS required only 12 (8–23) seconds, indicating that TTUS was significantly faster (p < 0.001). No significant correlation was found between the physician’s TTUS proficiency and image acquisition time. This study demonstrated that TTUS is more accurate and faster than EtCO2 measurement for confirming endotracheal tube placement during CPR, particularly in the context of PAPR usage in pandemic conditions.

Funder

National Research Foundation of Korea (NRF) grant funded by the Ministry of Science and ICT

Publisher

MDPI AG

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3