Serum Pepsinogens Combined with New Biomarkers Testing Using Chemiluminescent Enzyme Immunoassay for Non-Invasive Diagnosis of Atrophic Gastritis: A Prospective, Multicenter Study

Author:

Chapelle NicolasORCID,Osmola MalgorzataORCID,Martin JérômeORCID,Blin Justine,Leroy Maxime,Jirka Iva,Moussata Driffa,Lamarque Dominique,Olivier Raphael,Tougeron DavidORCID,Hay-Lombardie Anne,Bigot-Corbel Edith,Masson DamienORCID,Mosnier Jean-François,Matysiak-Budnik Tamara

Abstract

Background: Analysis of serum biomarkers for the assessment of atrophic gastritis (AG), a gastric precancerous lesion, is of growing interest for identification of patients at increased risk of gastric cancer. The aim was to analyze the diagnostic performance of serum pepsinogen testing using another method, chemiluminescent enzyme immunoassay (CLEIA), as well as of other new potential biomarkers. Material and Methods: The sera of patients considered at increased risk of gastric cancer and undergoing upper endoscopy collected in our previous prospective, multicenter study were tested for pepsinogen I (PGI) and II (PGII), interleukin-6 (IL-6), human epididymal protein 4 (HE-4), adiponectin, ferritin and Krebs von den Lungen (KL-6) using the CLEIA. The diagnostic performance for the detection of AG was calculated by taking histology as the reference. Results: In total, 356 patients (162 men (46%); mean age 58.6 (±14.2) years), including 152 with AG, were included. For the detection of moderate to severe corpus AG, sensitivity and specificity of the pepsinogen I/II ratio were of 75.0% (95%CI 57.8–87.9) and 92.6% (88.2–95.8), respectively. For the detection of moderate to severe antrum AG, sensitivity of IL-6 was of 72.2% (95%CI 46.5–90.3). Combination of pepsinogen I/II ratio or HE-4 showed a sensitivity of 85.2% (95%CI 72.9–93.4) for the detection of moderate to severe AG at any location. Conclusion: This study shows that PG testing by CLEIA represents an accurate assay for the detection of corpus AG. Additionally, IL-6 and HE-4 may be of interest for the detection of antrum AG. Mini-abstract: Pepsinogens testing by chemiluminescent enzyme immunoassay is accurate for the detection of corpus atrophic gastritis. IL-6 and HE-4 maybe of interest for the detection of antrum atrophic gastritis.

Funder

La ligue contre le cancer

Publisher

MDPI AG

Subject

Clinical Biochemistry

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3